User Switches C1 Submenu
90
Parameter
[Alphanumeric]
Description
Choices
Default
Hidden
item
Run
lockout
ENGLISH
(U3)
METRIC
(U3)
Mlt-Spd to
Dly 1
[C138]
(Multi-step Speed Command Delay x)
This parameter assigns multi-step speed
command to recognition delay timer x as
defined by the MSPD DELAY x (A1)
parameter. For more information, see
MULTI-STEP COMMAND DELAYS on
page 97.
mspd 1
[1]
mspd 2
[2]
mspd 3
[3]
mspd 4
[4]
mspd 5
[5]
mspd 6
[6]
mspd 7
[7]
mspd 8
[8]
mspd 9
[9]
mspd 10
[10]
mspd 11
[11]
mspd 12
[12]
mspd 13
[13]
mspd 14
[14]
mspd 15
[15]
none
[0]
NONE
Y
Y
Mlt-Spd to
Dly 2
[C139]
NONE
Y
Y
Mlt-Spd to
Dly 3
[C140]
NONE
Y
Y
Mlt-Spd to
Dly 4
[C141]
NONE
Y
Y
Priority Msg
[C142]
(Priority Message Enabling)
With Priority Message disabled the user
will not see priority messages meaning
faults and alarms will not be displayed on
the operator, but the faults will be placed
into the fault history and active fault lists
with the Fault LED on. Leave Priority
Message enabled when drive is not being
worked on.
Enable
[1]
Disable
[0]
ENABLE
N
N
Arb Select
i,ii
[C143]
With ARB SELECT set to ARB2 or ARB3,
the drive will calculate pretorque values
when movement is seen on the shaft. For
information on how to setup ARB, see on
page 57.
NOTE: ARB feature is disabled when PPT
Select (C1) is enabled.
Disable
[0]
ARB2
[2]
ARB3
[3]
Endat
Interp
[C144]
This parameter sets the feedback
interpolation rate mutilpiler for the EnDat
board for increased encoder feedback
resolution
NOTE:drive has an internal maximum
operating frequency explained on page 99
32
64
128
256
512
1024
128
N
i
Parameter accessible through
CLOSED LOOP (U9)
Operation
ii
Parameter accessibly through
PM (U9)
Operation
iii
Parameter accessible through
OPEN LOOP(U9)
Operation