![background image](http://html1.mh-extra.com/html/magnetek/hpv-900-series-2/hpv-900-series-2_technical-manual_3606659075.webp)
Drive A1 Submenu
53
Parameter
[
Alphanumeric]
Description
Units
Range
Default
Hidden
Item
Run
lockout
ENGLISH
(U3)
METRIC
(U3)
NTSD
Target Spd
[A187]
(Normal Terminal Stopping Device Target
Speed) Maximum speed at which drive will
run when NTSD is active.
ft/min
0.0
– 50.0
0.0
N
Y
m/s
0.000
– 0.250
0.000
NTSD
Threshold
1
[A188]
(Normal Terminal Stopping Device
Threshold 1) Magnitude of the maximum
allowable speed at the first NTSD check
point in the hoistway.
ft/min 0.0
– 1500.0
0.0
N
Y
m/s
0.000
– 7.600
0.000
NTSD
Threshold
2
[A189]
(Normal Terminal Stopping Device
Thresholds 2) Magnitude of the maximum
allowable speed at the second NTSD check
point in the hoistway.
ft/min 0.0
– 1500.0
0.0
N
Y
m/s
0.000
– 7.600
0.000
NTSD
Threshold
3
[A190]
(Normal Terminal Stopping Device
Thresholds 3) Magnitude of the maximum
allowable speed at the third NTSD check
point in the hoistway.
ft/min 0.0
– 1500.0
0.0
N
Y
m/s
0.000
– 7.600
0.000
Table 9: Drive A1 Submenu