Display D0 Menu
114
Power Data D2 Submenu
Parameter
[Alphanumeric]
Description
Units
Hidden
item
DC Bus Voltage
[D201]
(DC Bus Voltage) Measured voltage of the DC bus.
Volts
N
Motor Current
[D202]
(RMS Motor Current Output) Monitors the RMS
motor
output current.
Amps
N
Motor Voltage
[D203]
(Motor Voltage Output) Monitors the RMS motor
terminal line-line voltage.
Volts
N
Motor Frequency
[D204]
(Motor Frequency Output) Monitors the electrical
frequency of the motor output.
Hz
N
Motor Torque
[D205]
(Motor Torque Output) Calculated motor output
torque in terms of percent rated torque.
% rated
torque
N
Est No Load Curr
%
i
[D206]
(Estimated No Load Current
i
) Estimated no load
current of the motor calculated by the HPV 900 Series
2’s adaptive tune.
%
i
N
i
Est Rated RPM
i
[D207]
(Estimated Rated RPM
i
) Estimated rated rpm of the
motor calculated by the HPV 900 Series 2’s adaptive
tune.
RPM
i
N
i
Torque Reference
i,ii
[D208]
(Torque Reference
i
,ii
) Monitors the torque reference
used by the drive control.
% rated
torque
i
,ii
N
i
,ii
Flux Reference
i
[D209]
(Flux Reference
i
) Flux reference used by the vector
control of the drive.
% rated flux
i
N
i
Flux Output
i
[D210]
(Flux Output
i
) Measured value of the flux output.
% rated flux
i
N
i
% Motor Current
[D211]
(Percent Motor Current) Monitors the motor current as
a percent of rated motor current.
% rated
current
N
D-Curr
Reference
ii
[D214]
(
D-Axis Current Reference
ii
) This current is the
measured D-Axis Component of Current. It will be
non-zero at no-load and flux-weakening states
%
ii
N
ii
Power Output
[D212]
(Power Output) Calculated drive power output.
KW
N
Slip Frequency
i,
iii
[D213]
(Slip Frequency
i,
iii
) Displays the commanded slip
frequency of the motor
Hz
i,
iii
N
i,
iii
Motor Overload
[D215]
(Motor Overload) Displays the percentage of motor
overload trip level reached. Once this value reaches
100% the motor has exceeded its user defined
overload curve and a motor overload alarm is declared
by the drive.
%
N
Drive Overload
[D216]
(Drive Overload) Displays the percentage of drive
overload trip level reached. Once this value reaches
100% the drive has exceeded its overload curve and a
drive overload fault is declared.
%
N
Flux Current
[D217]
(Flux Current) Displays the flux producing current of
the motor.
% rated
current
Y
Torque Current
[D218]
(Torque Current) Displays the torque producing
current of the motor.
% rated
current
Y
Flux Voltage
[D219]
(Flux Voltage) Displays the flux voltage reference.
% rated volts
Y
Torque Voltage
[D220]
(Torque Voltage) Displays the torque voltage
reference.
% rated volts
Y
i
Parameter accessible through
CLOSED LOOP (U9)
Operation
ii
Parameter accessibly through
PM (U9)
Operation
iii
Parameter accessible through
OPEN LOOP(U9)
Operation