![background image](http://html1.mh-extra.com/html/magnetek/hpv-900-series-2/hpv-900-series-2_technical-manual_3606659135.webp)
Display D0 Menu
113
Parameter
[Alphanumeric]
Description
Units
Hidden
item
DCP Status
[D121]
(DCP Status Monitoring) - Used for monitoring signals given by
the drive serially to the control system when using DCP
Bit
Name Description/Reason
S0
Drive controller ready
S1
Travel active
S2
Advance warning active
S3
General fault active
S4
Speed below leveling value (v < 0,3 m/s)
S5
Desired distance / speed accepted (bit cleared for
emergency stop)
S6
Mechanical brake
S7
Error in last message received
1=true,
0=false
N
Measured PPR
[D122]
(Measured Pulses Per Revolution)
– Monitors the amount of
encoder pulses the drive reads per motor revolution
PPR
N
Endat Abs Fdbk
[D123]
(EnDat Absolute Feedback)
– Displays the angular position from
the EnDat encoder
None
N
Z Edge Count
[D124]
(Z Edge Count)
– Monitors the amount of index pulses from the Z
channel of an encoder.
None
N
NTSD Spd Fdbk 1
[D125]
(Normal Terminal Stopping Device Speed Feedback 1) - Monitors
the speed feedback coming from the encoder at the first NTSD
threshold assertion.
ft/min or
m/s
N
NTSD Spd Fdbk 2
[D126]
(Normal Terminal Stopping Device Speed Feedback 2) - Monitors
the speed feedback coming from the encoder at the second
NTSD threshold assertion.
ft/min or
m/s
N
NTSD Spd Fdbk 3
[D127]
(Normal Terminal Stopping Device Speed Feedback 3) - Monitors
the speed feedback coming from the encoder at the third NTSD
threshold assertion.
ft/min or
m/s
N
Table 20: Elevator Data D1 Submenu
D1 8:55
DCP Status
0000-0000
READY
RUN
USER
FAULT
TORQUE
LIMIT
SUB MENU
DATA ENTRY
Bit 0