![background image](http://html1.mh-extra.com/html/magnetek/hpv-900-series-2/hpv-900-series-2_technical-manual_3606659185.webp)
APPENDIX
– Safe-Off
163
Logic Input 8
† (C2)
Mech Brk Pick 2
Input for a normally open brake switch. The drive monitors
this input, and if it doesn’t switch as expected after a change
in Brake Pick/Autob
rake output, it will declare ‘Brake Pick
Fault 2’
Brake Pick Flt Ena (C1)
ENABLE
This parameter should be set to enable. In the event of a
Brake Pick Fault occurring, this parameter will change to
ACTIVE. The only way to clear the fault is to set this
parameter back to Enable and issuing a fault reset.
If a Brake Pick Fault occurs, and this parameter has changed
to ACTIVE, the only possible change is to ENABLE. If the
user tries to select DISABLE, the setting will revert to
ACTIVE.
Brake Pick Time (A1)
1 SEC
This parameter sets the window within which the brake pick
inputs should switch following a change in Brake Pick Output
* Any free Logic Output or Relay Coil can be used.
† Any free Logic Input can be used