Utility U0 Menu
116
Utility U0 Menu
U0
Parameter
[Alphanumeric]
Description
Default
Choices
Hidden
item
Run
lockout
U1 PASSWORD
For more information, see PASSWORD on page 119.
ENTER PASSWORD
[U101]
Allows the user to enter in a
password
12345
0
– 65535
N
N
NEW PASSWORD
[U102]
Used to change the password
N
N
PASSWORD LOCKOUT
[U103]
Used to enable and disable
password lockout
DISABLED
enabled
[1]
disabled
[0]
N
N
U2
HIDDEN ITEMS
For more information, see HIDDEN ITEMS on page 119.
HIDDEN ITEMS
[U201]
Selects if the “hidden”
parameters will be displayed on
the Digital Operator.
SHOW
ITEMS
show
items
[1]
hide items
[0]
N
N
U3 UNITS
For more information, see UNITS on page 119.
UNITS SELECTION
[U301]
Choose either Metric units or
standard English measurements
units
ENGLISH
English
[1]
Metric
[2]
N
Y
U4 OVRSPEED TEST
For more information, see OVERSPEED TEST on page 120.
OVERSPEED TEST?
[U401]
Allows for Overspeed Test to be
enabled via the digital operator
NO
no
[0]
yes
[1]
N
Y
U5 RESTORE DFLTS
For more information, see RESTORE DFLTS on page 121.
Rst Drive Dflts
[U501]
Resets all parameters to default
values except parameters in
MOTOR A5 and Utility U menus
Idle
[0]
Enter2Rst
[1]
N
Y
Rst Mtr Dflts
[U502]
Resets the parameters in the
MOTOR A5 to the defaults
defined by the MOTOR ID
Idle
[0]
Enter2Rst
[1]
N
Y
U6
DRIVE INFO
For more information, see DRIVE INFO on page 121.
DRIVE VERSION
[U601]
Shows the software version of
the drive software
N
N
BOOT VERSION
[U602]
Shows the lower level software
version of the drive
N
N
CUBE ID
[U603]
Displays the cube identification
number of the drive. If the main
control board is replaced on the
drive, this value will need to be
re-entered.
N
N
DRIVE TYPE
[U604]
Displays the drive type as
HPV900-Series 2.
N
N
U7
HEX MONITOR
For Magnetek personnel, see HEX MONITOR on page 122.
N
N
U8
LANGUAGE SEL
For more information, see LANGUAGE SEL on page 122.
LANGUAGE SELECT
[U801]
Selects language for operator
text
ENGLISH
English
[1]
Alpha-Num
[2]
N
N