APPENDIX
– Single Phase Ratings
194
Appendix
Single Phase Ratings
The HPV900 Series 2 drives may be run with a single phase VAC input. However, in order to run the
drive single phased, the drive must be derated by 60%. See Table 31 below for the single phased
ratings.
Rated
Input
Voltage
Continuous
Output Current
General Purpose
Rating
Continuous
Output Current
Elevator Duty Cycle
Rating
Maximum Output
Current
for 5 Sec
Frame
Size
Model Number
2
3
0
V
10
10.7
25
2
HPV900-2025-2E1-01
12.4
13.3
31
2
HPV900-2031-2E1-01
16.4
17.6
41
3.5
HPV900-2041-2E1-01
20.8
22.2
52
3.5
HPV900-2052-2E1-01
30
32.1
75
4
HPV900-2075-2E1-01
35.2
37.7
88
4
HPV900-2088-2E1-01
39.2
42
98
5
HPV900-2098-2E1-01
4
6
0
V
3.2
3.4
8
1
HPV900-4008-2E1-01
4.8
5.1
12
2
HPV900-4012-2E1-01
6.4
6.8
16
2
HPV900-4016-2E1-01
8.4
9
21
3
HPV900-4021-2E1-01
10.8
11.6
27
3
HPV900-4027-2E1-01
13.6
14.6
34
4
HPV900-4034-2E1-01
16.4
17.6
41
4
HPV900-4041-2E1-01
20.8
22.2
52
4
HPV900-4052-2E1-01
26
27.8
65
5
HPV900-4065-2E1-01
28.8
30.8
72
5
HPV900-4072-2E1-01
38.4
41.1
96
5
HPV900-4096-2E1-01
Table 31: Single Phase Ratings