Power Convert A4 Submenu
72
Parameter
[Alphanumeric]
Description
Units
Range
Default
Hidden
Item
Run
lockout
ENGLISH
(U3)
METRIC
(U3)
Load Sense
Time
[A431]
(Load Sense Time)
This is the duration that the drive
spends in the Recommended Travel
Direction mode to figure out the
direction that will require the least
amount of current (lightest load).
sec
0.00
– 1.50
0.00
N
N
Travel Dir Spd
[A432]
(Travel Dir Spd)
Used only if Rec Travel Spd (C1) is
set to geared. This is the speed the
drive will rotate the motor at in both
directions to overcome gearbox
friction to measure which direction
requires the least amount of current.
%
0.0
– 100.0
0.0
N
N
Autoalign
Volts
ii
[A433]
(Auto Alignment Voltage
ii
)
This parameter is used during Auto
Alignment. This parameter should
only be adjusted if a SPD DEV
FAULT following an auto alignment.
Default value is 10.
%
ii
5
– 20
ii
10
ii
N
ii
N
ii
Fan Off Delay
[A434]
(Fan Off Delay)
This parameter sets the amount of
time the drive will wait after the run
has been removed until the fans
turn off. Setting this value to
maximum of 999 will force the fans
to turn on immediately and
continuously run all the time
sec
0
– 999
20
N
N
Table 12: Power Convert A4 Submenu