Connecting the Cables
78
4.14
Cable Specifications for Control Block Wiring
Terminal Name
Cable size
1)
Specifications
mm
2
AWG
P9
–
P11
Multi-function input terminal
0.33
–
1.25
16
–
22
-
CM
Common terminal input
(5G common is used for
analog frequency inputs only).
Common earth for multi-function input
terminal
V2
Multi-function analog voltage
input terminal
Input voltage: 0
–
10 V or -10
–
10 V
I2
Multi-function analog current
input terminal
0
–
20 mA input
In
ternal resistance: 249 Ω
AO3
Multi-function analog voltage
output terminal
Maximum output voltage: 10 V
Maximum output current: 10 mA
AO4
Multi-function analog current
output terminal
Maximum output current: 20 mA
CM
24 V common
Common terminal for external 24 V power
source
3A
Multi-function relay 3 output A
Below AC 250 V/5 A, Below DC 30 V/5 A
3C
Multi-function relay 3
common terminal
Below AC 250 V/5 A, Below DC 30 V/5 A
4A
Multi-function relay 4 output A
Below AC 250 V/5 A, Below DC 30 V/5 A
4C
Multi-function relay 4
common terminal
Below AC 250 V/5 A, Below DC 30 V/5 A
5A
Multi-function relay 5 output A
Below AC 250 V/5 A, Below DC 30 V/5 A
5C
Multi-function relay 5
common terminal
Below AC 250 V/5 A, Below DC 30 V/5 A
2)
Use shielded, twisted-pair cables.
Summary of Contents for SV-iS7 Series
Page 17: ......
Page 114: ...Peripheral Devices 97 Group 2 ...
Page 115: ...Peripheral Devices 98 Group 3 ...
Page 116: ...Peripheral Devices 99 Group 4 ...
Page 159: ...Basic Functions 142 Code Description V1 Quantizing ...
Page 465: ...Safety Funtion STO Safe Torque Off 448 14 2 1 Safety Function Wiring Diagram ...