Using Monitor Functions
300
Code
Description
5
WHour Counter
Displays the inverter’s power consumption.
6
DCLink Voltage
Displays the inverter’s DC link voltage.
7
DI Status
Displays the input terminal status of the terminal
block. Starting from the right, it displays P1
–
P8.
8
DO Status
Displays the output terminal status of the terminal
block. Starting from the right, it displays Relay1,
Relay2, and Q1.
9
V1 Monitor[V]
Displays the input voltage value at terminal V1 (V).
10 V1 Monitor[%]
Displays the input voltage terminal V1 value as a
percentage. If -10V, 0V, and+10V is measured, -100%,
0%, and 100% will be displayed.
11 I1 Monitor[mA] Displays the magnitude of the current being input to
the I1 terminal of the inverter terminal block.
12 I1 Monitor[%]
Displays the above current as a percent. If the input
current is 0
–
20[mA], it is shown as 0
–
100%.
13 V2 Monitor[V]
Displays the voltage input of the I/O expansion
module
’s V2 terminal whe
n using the I/O expansion
module.
14 V2 Monitor[%]
Displays the V2 input voltage as a percent.
15 I2 Monitor[mA] Displays the current input for the I/O expansion
module
’s I2 terminal when using the I/O
expansion
module.
16 I2 Monitor[%]
Displays the I2 input current terminal value as a
percentage.
17 PID Output
Displays the PID controller’s output.
18 PID Ref Value
Displays the PID controller’s reference value.
19 PID Fdb Value
Displays the PID controller’s feedback volume.
20 Torque
Displays the torque reference value if torque
reference command mode (DRV-08) is set to a value
other than “Keypad” (0
or 1).
21 Torque Limit
Displays the torque limit value if the torque limit
setting method (CON-53) is set to a value other than
“Keypad” (0 or 1)
.
22 Trq Bias Ref
Displays the torque bias if the torque bias setting
method (CON-58) is set to a value other than
“Keypad”
(0 or 1).
23 Spd Limit
Displays the speed limit setting If the speed limiting
(CON-62) in Torque Control mode is set to a value
other than
“Keypad” (0 or 1)
.
Summary of Contents for SV-iS7 Series
Page 17: ......
Page 114: ...Peripheral Devices 97 Group 2 ...
Page 115: ...Peripheral Devices 98 Group 3 ...
Page 116: ...Peripheral Devices 99 Group 4 ...
Page 159: ...Basic Functions 142 Code Description V1 Quantizing ...
Page 465: ...Safety Funtion STO Safe Torque Off 448 14 2 1 Safety Function Wiring Diagram ...