Communication Function
355
Code
Description
11.5
Setting Operation Command and Frequency
After setting the DRV-06 (Cmd Source)
to “3 (Int 485)”
and DRV-07 (Freq Ref Src) to
“
7 (Int 485),
”
you can set common area parameters for the operation command and frequency via
communication.
Group
Code
LCD Display
Parameter Setting
Unit
DRV
06
Cmd Source
3
Int 485
-
07
Freq Ref Src
7
Int 485
-
11.6
Command Loss Protection
Configure the command loss decision standards and protective operations run when a
communication problem lasts for a specified period of time.
Group
Code
LCD Display
Parameter Setting
Unit
PRT
12
Lost Cmd Mode
1
Free-Run
-
13
Lost Cmd Time
-
1.0
Sec
14
Lost Preset F
-
0.00
Hz
OUT
31
–
33
Relay1,2, Q1
12
Lost Command
-