8.18.2
Automatic Energy Saving Operation
The inverter automatically finds the optimal energy saving point based on the motor rated
current (BAS-13) and the no-load current (BAS-14).
Group Code
Name
LCD Display
Setting
Setting Range
Unit
ADV
50
Energy saving
operation
E-Save Mode
2
Auto
0
–
2
-
BAS
13
Motor-rated
current
Rated Curr
Depends on
inverter capacity
1
–
1000
A
14
Motor no-load
current
Noload Curr
Depends on
inverter capacity
0.5
–
1000
A
If the operation frequency is changed, or acceleration or deceleration is carried out during an
energy saving operation, the actual acc/dec time may take longer than the set time due to the time
required to return to general operations from the energy saving operation.