IC-Module for EtherNet/IP
77 / 137
0x0026 Current assignment
of the shift chain
In this memory register you will find information about using the first
input and output register of the shift chain. You can detect whether
additional components (e. g. status LEDs, switches) are used or
whether all registers are used for the data transmission.
Modbus Register
0 x 0026
Value Range
0x00 – 0x07
Number of available bytes
1
Permanently stored
Yes
Access
Read Only
Meaning
Bit 0
Output register of the shift chain
0: all output registers are used for the data
transmission.
1: Output register 0 is used for the status
LEDs.
Bit 1, Bit 2
Input register of the shift chain
00: all registers are used for the data
transmission.
01: Input register 0 is used for fieldbus
switches.
10: Input register 0 and 1 are used for field-
bus switches.
0x0032 Script Enable
Register
In this register you have the option to activate or to deactivate the
execution of a script.
You will find information about creating a script in the "KUNBUS-
Scripter" documentation supplied.
Modbus Register
0x0032
Value Range
0x00 - 0xff
Default Value
0x00
Number of bytes available
1
Permanently stored
Yes
Access
Read/Write
Meaning
0
Deactivated
1
Activated
Memory Register