IC-Module for EtherNet/IP
129 / 137
4.6 Error Stack
In this menu you will find information about the errors that last
occurred. Please have these entries ready at hand when you contact
our support. We can help you faster by evaluating the entries.
If the value is 0x00000000, no error has occurred.
The Error Stack occupies the register 0x000a to 0x0011 and
provides space for 4 entries at a length of 32 bits each.
The register x+0 (0x….0000) contains the High-Word of the error.
The register x+1 (0x….0000) contains the Low-Word of the error.
If all four entries are occupied and another error occurs, this error will
replace the oldest error in the Error Stack. The latest error is always
displayed first.
--------------------------------------------------
KUNBUS-
IC
– Error Stack
--------------------------------------------------
<cr> = refresh; <Esc> = return
Entry 0: = 0x00000000
Entry 1: = 0x00000000
Entry 2: = 0x00000000
Entry 3: = 0x00000000
--------------------------------------------------
>
4.7 Script Interpreter Status
In this menu you will find information about the current Script-Status.
--------------------------------------------------
KUNBUS-
IC
- Script Interpreter Status
--------------------------------------------------
<cr> = refresh; <Esc> = return
Port used by script: CDI
Execution status: Stopped
Loop counter: 0
--------------------------------------------------
>
CDI