IC-Module for EtherNet/IP
63 / 137
0x0008 Current Settings of
the SDI Parity Bit
In this register you will find information about the currently used
settings of the parity bit for the data transmission of the serial
interface (SDI ).
Modbus Register
0x0008
Value Range
0x0000-0x0002
Default Value
0x0000
Number of available Bytes
2
Permanently stored
No
Access
Read Only
Meaning
0x0000
Even parity (Even, 1 stop bit)
0x0001
Odd parity (Odd, 1 stop bit)
0x0002
No parity (2 stop bits)
0x0012 Set bitrate for the CDI
interface
In this memory register you have the option, to set the Bitrate for the
CDI
The new settings are applied after a reset.
Modbus Register
0x0012
Value Range
0x01-0x07
Default Value
0x07 (115200 bit/s)
Number of bytes available
1
Permanently stored
Yes
Access
Read/Write
Meaning
0x01
2400 bit/s
0x02
4800 bit/s
0x03
9600 bit/s
0x04
19200 bit/s
0x05
38400 bit/s
0x06
56700 bit/s
0x07
115200 bit/s
NOTICE
Automatic bitrate detection with the CDI is not possible.
Ø
If the configuration that was entered is invalid, the corresponding
registers use the following settings in order not to block the interface by
incorrect data:
è
9600 bit/s, 1 stop bit, even parity
Memory Register