IC-Module for EtherNet/IP
108 / 137
NOTICE! In the event of an invalid mapping (e.g. due to a
register address outside the permitted input range or a register
number that is too high) an error message appears.
Default data in Data Broker
In this menu you have the option, to define the default data for
consumers used in the event of invalid production data.
If the data in the input registers should be invalid e.g. because no
data has arrived anymore from outside, the Data Broker uses the
following values:
– All bits are 1
– All bits are 0
– All bits remain unchanged
--------------------------------------------------
KUNBUS-
IC
– Default data in data broker
--------------------------------------------------
1 - all data bit are zero
2 - all data bit are one
3 - old production values are used
--------------------------------------------------
>
Production valid time
In this menu you have the option,to determine the validity period of
the register contents to be read out.
The value range of the validity periods can be defined between 1 and
255 ms. With “0” you can deactivate the function
If no new data from the producer should arrive in the input registers
within the predefined period, the Data Broker uses the data set
among the default values.
--------------------------------------------------
KUNBUS-
IC
– Production valid time (0 = disabled)
--------------------------------------------------
>
CDI