119 / 137
2.11 Script Interpreter
In this menu you have the option, to activate or deactivate a script
and to select the desired port.
NOTICE
Please note that activation of a script influences the individual port.
Never activate a script with the setting "Port used by script: CDI" if you do
not have a fully functional SDI interface for accessing the parameter
memory registers! In such a case, your module is no longer configurable!
You can switch the status between disabled and enabled by entering
[1]+[Return].
– You can define the SDI or CDI as port. You switch between both
options by entering [2]+[Return].
--------------------------------------------------
KUNBUS-
IC
- Script Interpreter
--------------------------------------------------
1 - State: disabled
2 - Port used by script: SDI
--------------------------------------------------
>
2.12 Reset to Factory
Settings
With this option, you reset all parameters of the IC module to the
default values.
You have to confirm the selection by entering the number "36" for
reasons of security. Afterwards, the module restarts.
NOTICE
Loss of all settings
Bear in mind that with this function you will delete all settings that you have
previously made.
CDI