IC-Module for EtherNet/IP
50 / 137
Configuration using the SDI
The KUNBUS-IC has a UART interface with 3.3 V logic levels. Your
main board must convert these lines to standardised RS-485 signals
so that Modbus/RTU devices can access these. Conversion to
standardised RS-232 signals is generally necessary for
communication with a PC. The base board of the evaluation board
has both interfaces that can each be selected via jumpers.
Configuration using the SDI requires a Modbus master device.
One of the following devices is suitable for this:
– Master computer,
– Control panel,
– Programming device,
– SPS with the possibility of Modbus-RTU communication.
To communicate with the SDI of the module using a PC, you need
Modbus software (e.g. Modpoll).
Also see about this
2
Setting up a Serial Connection [
}
95]
5.3 Firmware Update
If a firmware update is required, please contact our support
([email protected]). We will be delighted to provide you with all the
information you need for your product.
Commissioning