Terminal error messages
8
Faults of the electrics/electronics
8.1
Comprima F 125 - 1, Comprima F 125 XC - 1, Comprima F 155 - 1, Comprima F 155 XC - 1, Comprima V 150 - 1,
Comprima V 150 XC - 1, Comprima V 180 - 1, Comprima V 180 XC - 1, Comprima V 210 XC - 1
Comfort 1.0_en
79
Possible cause
Remedy
FMI 2: The tailgate is open while starting up the machine.
The tailgate is not locked.
Close the tailgate using the tractor hydraulics.
The sensor is defective or has
been incorrectly set.
Check and adjust sensors B11 /B12 “Lock hook bale
chamber left/Lock hook bale chamber right”,
522048-
Tailgate
Possible cause
Remedy
FMI 2: – The tailgate is open during road operating mode.
The tailgate is not locked.
Close the tailgate using the tractor hydraulics.
The sensor is defective or has
been incorrectly set.
Check and adjust sensors B11 /B12 “Lock hook bale
chamber left/Lock hook bale chamber right”,
522049-
Tailgate
Possible cause
Remedy
FMI 2: An open tailgate was detected, although no tying has occurred since it was last closed.
The baling pressure is too
high.
Start net or chamber film wrapping in manual operation and
have the round bale tied,
The bale chamber is overfilled
and it was thus opened by the
round bale.
Manually empty the bale chamber:
The tailgate is not correctly
locked.
Open and close the tailgate again.
522101-
B01
Sensor B01 “Speed of bale chamber”
Possible cause
Remedy
FMI 4: There is a cable break, cable break/short circuit, general error or undervoltage.
FMI 5: There is a cable break, general error or overload.
The sensor is damaged ex-
ternally.
Check sensor and wiring for damage,
The sensor wiring is faulty.
522102-
B02
Sensor B02 “Tying process active”
Possible cause
Remedy
FMI 4: There is a cable break, cable break/short circuit, general error or undervoltage.
FMI 5: There is a cable break, general error or overload.
The sensor is damaged ex-
ternally.
Check sensor and wiring for damage,
The sensor wiring is faulty.
522105-
B05
Sensor B05 “Slip floor conveyor”