![Krone Comprima F 125 XC-1 Operating Instructions Manual Download Page 328](http://html1.mh-extra.com/html/krone/comprima-f-125-xc-1/comprima-f-125-xc-1_operating-instructions-manual_2004803328.webp)
8
Terminal error messages
8.1
Faults of the electrics/electronics
84
Comprima F 125 - 1, Comprima F 125 XC - 1, Comprima F 155 - 1, Comprima F 155 XC - 1, Comprima V 150 - 1,
Comprima V 150 XC - 1, Comprima V 180 - 1, Comprima V 180 XC - 1, Comprima V 210 XC - 1
Comfort 1.0_en
522420-
E20/E21
Actuator E20/E21 "Working lights net roll (for the “Net and chamber film wrapping” and
“Working lights” version)"
Possible cause
Remedy
FMI 5: There is a cable break, general error or overload.
FMI 6: There is a short circuit to ground or amperage is too high.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage,
.
The wiring of the actuator is
faulty.
522421-
E21
Actuator E21 "Working lights chamber film wrapping (for the “Net and chamber film
wrapping” version)"
Possible cause
Remedy
FMI 5: There is a cable break, general error or overload.
FMI 6: There is a short circuit to ground or amperage is too high.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage,
.
The wiring of the actuator is
faulty.
522422-
E22/E23
Actuator E22/E23 “Maintenance lighting side hood left/right”
Possible cause
Remedy
FMI 5: There is a cable break, general error or overload.
FMI 6: There is a short circuit to ground or amperage is too high.
The actuator is damaged ex-
ternally.
Check actuator and wiring for damage,
.
The wiring of the actuator is
faulty.
522500-
EEPROM
Possible cause
Remedy
FMI 13: The wrong configuration values were saved.
An invalid machine type has
been specified.
Adjust the machine type.
Restart the machine.
The configuration parameters
of the machine are invalid.
Configure the machine correctly.
Restart the machine.
522530-
KMB1