![Krone Comprima F 125 XC-1 Operating Instructions Manual Download Page 301](http://html1.mh-extra.com/html/krone/comprima-f-125-xc-1/comprima-f-125-xc-1_operating-instructions-manual_2004803301.webp)
Terminal menus
7
Menu 15 "Settings"
7.21
Comprima F 125 - 1, Comprima F 125 XC - 1, Comprima F 155 - 1, Comprima F 155 XC - 1, Comprima V 150 - 1,
Comprima V 150 XC - 1, Comprima V 180 - 1, Comprima V 180 XC - 1, Comprima V 210 XC - 1
Comfort 1.0_en
57
15-1
1
state:
5,0V
3,5V
2,5V
1,0V
2,4V 3,5V
2,4V
B61
M1
EQ003-106
ü
Menu 15-1 “Sensor test” is open.
ü
Sensor B61 “Tying 1 (passive)” has been selected.
Saving is only possible if the bar is inside the bottom or top rectangle of the bargraph.
Setting the feed position
RP000-043
The distance (X) between the pivot point of the ratchet mechanism (1) and the adjusting lever
(2) must be
X=285–295 mm
.
With net and chamber film wrapping, the feed position has been optimally set if the feed rocker
arm moves as close as possible to the stop to ensure the distance is 5 mm, see chapter
Chamber film wrapping, “Checking and setting the feed position”.
With net wrapping: Press the key
or
until the tying actuator extends far enough
and the dimension is
X=285–295 mm
.
Press
.
Æ
The set position is saved.