![Krone Comprima F 125 XC-1 Operating Instructions Manual Download Page 308](http://html1.mh-extra.com/html/krone/comprima-f-125-xc-1/comprima-f-125-xc-1_operating-instructions-manual_2004803308.webp)
8
Terminal error messages
8.1
Faults of the electrics/electronics
64
Comprima F 125 - 1, Comprima F 125 XC - 1, Comprima F 155 - 1, Comprima F 155 XC - 1, Comprima V 150 - 1,
Comprima V 150 XC - 1, Comprima V 180 - 1, Comprima V 180 XC - 1, Comprima V 210 XC - 1
Comfort 1.0_en
FMI
Meaning
19
There is a CAN communication failure.
20
The data deviates upwards.
21
The data deviates downwards.
31
The condition has been fulfilled.
8.1.2
Remedying sensor/actuator error
Components must be repaired or replaced by a qualified specialist workshop only.
Before contacting the dealer, collect the following information about the error message:
Note the error number and the respective FMI (
) that are shown on the
display.
Shut down and safeguard the machine, Shutting down and safeguarding the machine.
Check sensor/actuator externally for damage.
Æ
If the sensor/actuator is damaged, replace the sensor/actuator.
Æ
If the sensor/actuator is not damaged, continue with the next test step.
Check connector cable and plug connection for damage and tightness.
Æ
If the connector cable/plug connection is damaged, replace the connector cable/plug
connection.
Æ
If the sensor/actuator is not damaged, continue with the next test step.
Perform an actuator test in case of an actuator error to identify the actuator status,
.
If a sensor is defective, run a sensor test to identify the sensor status,
.
The more information the dealer has, the easier it is to eliminate the cause of the error.
8.1.3
Error list with all error messages
General aspects on error causes
The sequence of the possible causes listed was selected so that the easiest tests with regard to
accessibility/handling are listed first which makes troubleshooting easier.
Following the stated references, you will get to the individual test steps of the possible error
causes. When all test steps have been processed and the error has still not been remedied, the
next possible cause must be checked or the next error in the error list of the terminal must be
remedied. The test steps do not contain the components to be tested in detail such as contacts,
plug designations etc. but must be selected by means of the circuit diagram.
520192-
KBT
KRONE operating terminal (KOT)
Possible cause
Remedy
FMI 19: There is a network/CAN error.
The wiring is faulty.
Check wiring,
.
The operating terminal is de-
fective.
Note the error number and the FMI. Then contact the
dealer.
520193-
KBT
KRONE operating terminal (KOT)