Terminal error messages
8
Faults of the electrics/electronics
8.1
Comprima F 125 - 1, Comprima F 125 XC - 1, Comprima F 155 - 1, Comprima F 155 XC - 1, Comprima V 150 - 1,
Comprima V 150 XC - 1, Comprima V 180 - 1, Comprima V 180 XC - 1, Comprima V 210 XC - 1
Comfort 1.0_en
77
522023-
Feed roller for net wrapping/chamber film wrapping
Possible cause
Remedy
FMI 7: The speed of the feed roller is below the minimum when the net is pulled.
The machine is blocked.
Remove the blockage.
The PTO shaft is rotating too
slowly.
Set a higher rotational speed via the tractor on the PTO
shaft.
522024-
Net wrapping
Possible cause
Remedy
FMI 7: The net has not been cut. The net is not cleanly cut.
The cutting unit is blunt.
Remove contamination from the cutting unit.
Replace the cutting unit.
The cutting unit is not
clamped.
Remove contamination from the cutting unit.
Check and set the cutting position,
The tying actuator is defect-
ive.
Check the tying actuator.
The wire rope is defective.
Check the wire rope.
522024-
Chamber film wrapping
Possible cause
Remedy
FMI 7: The film is not cut. The film is not cleanly cut.
The cutting unit is blunt.
Remove contamination from the cutting unit.
Replace the cutting unit.
The cutting unit is not
clamped.
Remove contamination from the cutting unit.
Check and set the cutting position,
The tying actuator is defect-
ive.
Check the tying actuator.
The wire rope is defective.
Check the wire rope.
522035-
MAX
Filling the bale chamber
Possible cause
Remedy
FMI 0: The maximum filling of the bale chamber has been reached. The round bale is forcibly
tied, even if it should be manually tied. This may damage the machine in the long term.
Too many crops loaded too
quickly into the bale chamber.
Reduce the driving speed earlier and adjust to the swath.
Advance signalling has not
been set.
Set advance signalling,
Advance signalling has been
ignored and the bale chamber
loaded with too many crops.
Observe advance signalling.
Do not permanently overload the bale chamber.
522038-
Bale chamber, bale formation conveyor