Korenix Technology Co., Ltd.
Industrial
Layer 3 Managed Ethernet Switch
_____________________________________________________________________________
Industrial Layer 3 Managed Ethernet SwitchUser Manual
Page: 911/1246
Disabled
Blocking
Listening
Learning
Forwarding
Broken
Port Role
- Each MST Bridge Port that is enabled is assigned a Port Role for each spanning tree.
The port role will be one of the following values: Root Port, Designated Port, Alternate Port, Backup
Port, Master Port, or Disabled Port.
Admin Mode
- The Port control administration state. The port must be enabled in order for it to be
allowed into the network. The factory default is enabled.
LACP Mode
- Indicates the Link Aggregation Control Protocol administration state. The mode must
be enabled in order for the port to participate in Link Aggregation.
Physical Status
–Indicates the port speed and duplex mode for Physical interfaces. Does not report
Physical Status for LAG interfaces. Physical status is unknown when a port is down.
Physical Status
- Indicates the port speed and duplex mode.
Link Status
- Indicates whether the Link is up or down.
Link Trap
- Indicates whether or not the port will send a trap when link status changes.
ifIndex
- Indicates the ifIndex of the interface table entry associated with this port.
Flow Control
- Indicates the status of flow control on this port.
Broadcast Storm Control
– Indicates whether broadcast storm control is enabled or disabled for
the port. The factory default is disabled.
Bcast Rate
- Set the packet rate value on selected interface. The valid values are from (1 to
14880000) pps.
Multicast Storm Control
–Indicates whether multicast storm control is enabled or disabled for the
port. The factory default is disabled.
Mcast Rate
- Set the packet rate value on selected interface. The valid values are from (1 to
14880000) pps.
Unicast Storm Control
–Indicates whether unicast storm control is enabled or disabled for the port.
The factory default is disabled.
Ucast Rate
- Set the packet rate value on selected interface. The valid values are from (1 to
14880000) pps.
Command Buttons
Refresh
– Refresh the configuration value again.