Korenix Technology Co., Ltd.
Industrial
Layer 3 Managed Ethernet Switch
_____________________________________________________________________________
Industrial Layer 3 Managed Ethernet SwitchUser Manual
Page: 1213/1246
9.7.5.2
Configuring DVMRP Interface Configuration
Selection Criteria
Interface
- Select the interface for which data is to be configured. You must configure at least
one router interface before you configure a DVMRP interface. Otherwise you will see a message
telling you that no router interfaces are available, and the configuration screen will not be
displayed.
Configurable Data
Interface Mode
- Select enable or disable from the pull down menu to set the administrative mode
of the selected DVMRP routing interface.
Interface Metric
- Enter the DVMRP metric for the selected interface. This value is sent in DVMRP
messages as the cost to reach this network. Valid values are from (1 to 31).
Command Buttons
Submit
- Update the switch with the values on the screen. If you want the switch to retain the
new values across a power cycle you must perform a save.