7.3.2.45
ip ospf mtu-ignore
ip ospf mtu-ignore
command disables OSPF maximum transmission unit (MTU) mismatch detection.
OSPF Database Description packets specify the size of the largest IP packet that can be sent without
fragmentation on the interface. W hen a router receives a Database Description packet, it examines
the MTU advertised by the neighbor. By default, if the MTU is larger than the router can accept, the
Database Description packet is rejected and the OSPF adjacency is not established.
no ip ospf
mtu-ignore
command enables the OSPF MTU mismatch detection.
Syntax
ip ospf mtu-ignore
no ip ospf mtu-ignore
Default Setting
Enable
d
Command Mode
Interface Config
7.3.2.46
router-id
router-id
command sets a 4-digit dotted-decimal number uniquely identifying the router ospf id. The
<ipaddress> is a configured value.
Syntax
router-id <ipaddress>
Default Setting
None
Command Mode