Korenix Technology Co., Ltd.
Industrial
Layer 3 Managed Ethernet Switch
_____________________________________________________________________________
Industrial Layer 3 Managed Ethernet SwitchUser Manual
Page: 843/1246
Alignment Errors
- The total number of packets received that had a length (excluding framing bits,
but including FCS octets) of between 64 and 1518 octets, inclusive, but had a bad Frame Check
Sequence (FCS) with a non-integral number of octets.
Rx FCS Errors
- The total number of packets received that had a length (excluding framing bits, but
including FCS octets) of between 64 and 1518 octets, inclusive, but had a bad Frame Check
Sequence (FCS) with an integral number of octets
Overruns
- The total number of frames discarded as this port was overloaded with incoming
packets, and could not keep up with the inflow.
Receive Packets Discarded
- A count of valid frames received which were discarded (i.e. filtered)
by the forwarding process.
802.3x Pause Frames Received
- A count of MAC Control frames received on this interface with an
opcode indicating the PAUSE operation. This counter does not increment when the interface is
operating in half-duplex mode.
Unacceptable Frame Type
- The number of frames discarded from this port due to being an
unacceptable frame type.
Total Packets Transmitted (Octets)
- The total number of octets of data (including those in bad
packets) transmitted on the network (excluding framing bits but including FCS octets). This object
can be used as a reasonable estimate of Ethernet utilization. If greater precision is desired, the
etherStatsPkts and etherStatsOctets objects should be sampled before and after a common interval.
Packets Transmitted 64 Octets
- The total number of packets (including bad packets) received that
were 64 octets in length (excluding framing bits but including FCS octets).
Packets Transmitted 65-127 Octets
- The total number of packets (including bad packets) received
that were between 65 and 127 octets in length inclusive (excluding framing bits but including FCS
octets).
Packets Transmitted 128-255 Octets
- The total number of packets (including bad packets)
received that were between 128 and 255 octets in length inclusive (excluding framing bits but
including FCS octets).
Packets Transmitted 256-511 Octets
- The total number of packets (including bad packets)
received that were between 256 and 511 octets in length inclusive (excluding framing bits but
including FCS octets).
Packets Transmitted 512-1023 Octets
- The total number of packets (including bad packets)
received that were between 512 and 1023 octets in length inclusive (excluding framing bits but
including FCS octets).
Packets Transmitted 1024-1518 Octets
- The total number of packets (including bad packets)
received that were between 1024 and 1518 octets in length inclusive (excluding framing bits but
including FCS octets) and were otherwise well formed. This counter has a max increment rate of 815
counts per sec at 10 Mb/s.
Maximum Frame Size
- The maximum Ethernet frame size the interface supports or is configured,
including Ethernet header, CRC, and payload. (1518 to 9216). The default maximum frame size is
1518.
Total Packets Transmitted Successfully
- The number of frames that have been transmitted by
this port to its segment.
Unicast Packets Transmitted
- The total number of packets that higher-level protocols requested
be transmitted to a subnetwork-unicast address, including those that were discarded or not sent.
Multicast Packets Transmitted
- The total number of packets that higher-level protocols requested
be transmitted to a Multicast address, including those that were discarded or not sent.
Broadcast Packets Transmitted
- The total number of packets that higher-level protocols