Korenix Technology Co., Ltd.
Industrial
Layer 3 Managed Ethernet Switch
_____________________________________________________________________________
Industrial Layer 3 Managed Ethernet SwitchUser Manual
Page: 898/1246
9.2.16.3
Time Range Entry Configuration
Selection Criteria
Time Range Name
- Select the time range for which to create or delete a time entry.
Time Range Entry
- Select an existing time range entry or select 'Create New Time Range Entry' to
add a new time range entry. New time range entries cannot be created if the maximum number of
entries has been reached. A time range entry can either be an absolute entry or periodic entry. Only
one absolute entry can be configured per time range.
Configurable Data
Time Range Entry ID
- Enter a whole number in the range of (1 to 10) that will be used to identify the
time range entry.
Time Range Entry Type
- Specify what type of entry should be created. The choices are Absolute
or Periodic.
Start Date
- Select the day of the month of the absolute entry's start date.
Start Month
- Select the month of the absolute entry's start date.
Start Year
- Select the year of the absolute entry's start date.
Start Time
- Specify the absolute start time in hh:mm format.
End Date
- Select the day of the month of the absolute entry's end date.
End Month
- Select the month of the absolute entry's end date.
End Year
- Select the year of the absolute entry's end date.
End
Time
- Specify the absolute end time in hh:mm format.
Absolute Start Date and Time
- Specifies the absolute entries start date and time.
Absolute End Date and Time
- Specifies the absolute entries end date and time.
Applicable Days
- Specify the applicable day(s) of week for periodic entry.
-
Option 'Daily' indicates that periodic entry is applicable on every day of week.
-
Option 'W eekdays' indicates that periodic entry is applicable only on weekdays.
-
Option 'W eekend' indicates that periodic entry is applicable only on weekend.