9.2.13
Managing LLDP-MED
9.2.13.1
Configuring LLDP-MED Global Configuration Page
Configurable Data
Fast Start Repeat Count
- Specifies the number of LLDP PDUs that will be transmitted when the
protocol is enabled. The range is from (1 to 10). Default value of fast repeat count is 3.
Non-Configurable Data
Device Class
- Specifies local device's MED Classification. There are four different kinds of devices;
three of them represent the actual end points (classified as Class I Generic [IP Communication
Controller etc.], Class II Media [Conference Bridge etc.], Class III Communication [IP Telephone
etc.]). The fourth device is Network Connectivity Device, which is typically a LAN Switch/Router,
IEEE 802.1 Bridge, IEEE 802.11 W ireless Access Point etc.
Command Buttons
Submit
- Send the updated screen to the switch and cause the changes to take effect on the switch
but these changes will not be retained across a power cycle unless a save is performed.