SUPER LONG FRONT BOOM AND ARM
ATTACHMENTS AND OPTIONS
6-58
EVERY 100 HOURS SERVICE
6
LUBRICATING
The minimum greasing interval is 100 hours.
However, more frequent greasing will be required depending on conditions/environment
1.
Set the work equipment in the greasing posture below, then lower the work equipment to the ground and stop
the engine.
2.
Using a grease pump, pump in grease through the grease fittings shown by arrows.
3.
After greasing, wipe off any old grease that was pushed out.
1. Arm cylinder foot pin (1 point)
2. Boom-Arm coupling pin (1 point)
3. Arm cylinder rod end (1 point)
1
5
6
3
4
7, 8
9
2
AM091510C
1
AM091520C
2
3
4