DETAILED CONTROLS AND GAUGES
OPERATION
3-10
REMARK
The colors lighting up the monitors related to the emergency stop items, caution items, and basic check items are
as follows.
AA: Screen for standard
BB: Screen with all lamps lighted up
CC: Maintenance time warning screen
Type of monitor
Color when monitor lights up
When
normal
When
abnormal
At low
temperature
(1)
Engine coolant temperature monitor
Blue
Red
White
(2)
Hydraulic oil temperature monitor
Blue
Red
White
(3)
Fuel level monitor
Blue
Red
-
(4)
Radiator coolant level monitor
OFF
Red
-
(5)
Charge level monitor
OFF
Red
-
(6)
Engine oil pressure monitor
OFF
Red
-
(7)
Engine oil level monitor
OFF
Red
-
(8)
Air cleaner clogging monitor
OFF
Red
-
(9)
Water separator monitor
OFF
Red
-
(10) Maintenance interval monitor
OFF
Red
-