TROUBLES AND ACTIONS
OPERATION
3-210
Chassis
3
q
( ): Always contact your Komatsu distributor when dealing with these items.
q
In cases of problems or causes which are not listed below, contact your Komatsu distributor for repairs.
Problem
Main causes
Remedy
Speed of travel, swing, boom, arm,
bucket is slow
•Lack of hydraulic oil
•Add oil to specified level, see
CHECK BEFORE STARTING
Pump generates abnormal noise
(sucking in air)
•Clogged element in hydraulic
tank strainer, lack of oil
•Clean, see EVERY 2000
HOURS SERVICE
Excessive rise in hydraulic oil
temperature
•Loose fan belt
•Dirty oil cooler
•Lack of hydraulic oil
(•Check fan belt tension, replace)
•Clean, see EVERY 500 HOURS
SERVICE
•Add oil to specified level, see
CHECK BEFORE STARTING
Track comes off
•Track too loose
•Adjust track tension, see WHEN
REQUIRED
Abnormal wear of sprocket
Boom rises slowly, does not rise
•Lack of hydraulic oil
•Add oil to specified level,
CHECK BEFORE STARTING
Does not swing
•Swing lock switch still applied
•Turn swing lock switch OFF
Summary of Contents for PC350LC-8
Page 2: ......
Page 3: ...FOREWORD 11...
Page 12: ...PRODUCT INFORMATION FOREWORD 1 10 SERVICE METER LOCATION 1 On top of the machine monitor...
Page 278: ...TROUBLES AND ACTIONS OPERATION 3 214...
Page 366: ...MAINTENANCE PROCEDURE MAINTENANCE 4 88...
Page 367: ...SPECIFICATIONS 15...
Page 371: ...SPECIFICATIONS SPECIFICATIONS 5 5...
Page 372: ...SPECIFICATIONS SPECIFICATIONS 5 6...
Page 432: ...SUPER LONG FRONT BOOM AND ARM ATTACHMENTS AND OPTIONS 6 60...
Page 496: ...SPECIFICATIONS HIGH REACH DEMOLITION MANUAL 7 64...
Page 497: ...INDEX 18...
Page 498: ...INDEX 8 2...
Page 501: ...COLOPHON 18...