MAINTENANCE
MAINTENANCE PROCEDURE
4-83
REPLACE ACCUMULATOR (FOR CONTROL CIRCUIT)
4
Replace the accumulator every 2 years or every 4000 hours, whichever comes sooner.
WARNING
The accumulator is charged with high-pressure nitrogen gas, so mistaken operation may cause an explo-
sion, which will lead to serious injury or damage. When handling the accumulator, always do as follows.
The pressure in the hydraulic circuit cannot be completely removed. When removing the hydraulic equip-
ment, do not stand in the direction that the oil spurts out when carrying out the operation. In addition,
loosen the bolts slowly when carrying out the operation.
Do not disassemble the accumulator.
Do not bring it near flame or dispose of it in fire.
Do not make holes in it or weld it.
Do not hit it, roll it, or subject it to any impact.
When disposing of the accumulator, the gas must be released. Please contact your Komatsu distributor to
have this work carried out.
If operations are continued after the performance of the accu-
mulator has dropped, it will be impossible to release the
remaining pressure in the hydraulic circuit if there should be a
failure on the machine. Please ask your Komatsu distributor to
replace the accumulator.
The accumulator is installed to the position shown in the dia-
gram on the right.
Summary of Contents for PC350LC-8
Page 2: ......
Page 3: ...FOREWORD 11...
Page 12: ...PRODUCT INFORMATION FOREWORD 1 10 SERVICE METER LOCATION 1 On top of the machine monitor...
Page 278: ...TROUBLES AND ACTIONS OPERATION 3 214...
Page 366: ...MAINTENANCE PROCEDURE MAINTENANCE 4 88...
Page 367: ...SPECIFICATIONS 15...
Page 371: ...SPECIFICATIONS SPECIFICATIONS 5 5...
Page 372: ...SPECIFICATIONS SPECIFICATIONS 5 6...
Page 432: ...SUPER LONG FRONT BOOM AND ARM ATTACHMENTS AND OPTIONS 6 60...
Page 496: ...SPECIFICATIONS HIGH REACH DEMOLITION MANUAL 7 64...
Page 497: ...INDEX 18...
Page 498: ...INDEX 8 2...
Page 501: ...COLOPHON 18...