OPERATION
DETAILED CONTROLS AND GAUGES
3-23
Hydraulic Oil Temperature Gauge
This meter (11) shows the hydraulic oil temperature.
During normal operations, the indicator should be in the green
range.
If the indicator enters the red range (A) during operations, the
hydraulic oil temperature is 102°C or more. Run the engine at
low idling or stop it and wait for the hydraulic oil temperature to
go down.
q
(A) - (B): Red range
q
(A) - (D): Green range
q
(D) - (C): White range
REMARK
When the indicator reaches red range (A), the hydraulic oil temperature is as follows.
Red range (A) position: 102°C or more
Red range (B) position: 105°C or more
When the indicator is in red range (A) - (B), hydraulic oil temperature monitor (E) shows the abnormality display.
When the engine is started, if the indicator is at position (C) and the hydraulic oil temperature is 20°C, hydraulic oil
temperature monitor (E) shows the low-temperature display. If this happens, carry out the warm-up operation. For
details, see “Hydraulic Equipment Warm Up (3-145)“.
Display (G) at low temperatures: Monitor background (K) is
white
Display (H) at correct temperatures: Monitor background (K) is
blue
Display (J) when condition is abnormal: Monitor background
(K) is red
Fuel Gauge
This meter (12) shows the amount of fuel remaining in the fuel
tank.
During normal operations, the indicator should be in the green
range.
If the indicator starts to enter red range (A) during operation,
there is less than 100 liters of fuel remaining, so carry out
inspection and add fuel.
q
(A) - (B): Indicates red range
q
(A) - (C): Indicates green range
REMARK
When the indicator reaches red range (B), there is less than 60 liters of fuel remaining.
When the indicator is in the red range (B), fuel level monitor (D) lights up red.
The correct fuel level may not be displayed for a short time when the starting switch is turned ON, but this is not an
abnormality.
Summary of Contents for PC350LC-8
Page 2: ......
Page 3: ...FOREWORD 11...
Page 12: ...PRODUCT INFORMATION FOREWORD 1 10 SERVICE METER LOCATION 1 On top of the machine monitor...
Page 278: ...TROUBLES AND ACTIONS OPERATION 3 214...
Page 366: ...MAINTENANCE PROCEDURE MAINTENANCE 4 88...
Page 367: ...SPECIFICATIONS 15...
Page 371: ...SPECIFICATIONS SPECIFICATIONS 5 5...
Page 372: ...SPECIFICATIONS SPECIFICATIONS 5 6...
Page 432: ...SUPER LONG FRONT BOOM AND ARM ATTACHMENTS AND OPTIONS 6 60...
Page 496: ...SPECIFICATIONS HIGH REACH DEMOLITION MANUAL 7 64...
Page 497: ...INDEX 18...
Page 498: ...INDEX 8 2...
Page 501: ...COLOPHON 18...