MAINTENANCE SCHEDULE
MAINTENANCE
4-20
MAINTENANCE INTERVAL FOR HYDRAULIC BREAKER
4
For machine equipped with a hydraulic breaker, the hydraulic oil deteriorates faster than for normal bucket digging
operations, so set the maintenance intervals as follows.
q
Replace hydraulic filter element
On a new machine, replace the element after the first 100
to 150 hours, then carry out further replacement of the ele-
ment according to the table on the right.
q
Change oil in hydraulic tank
Change the oil according to the table on the right.
q
Replacing additional filter element for breaker (if
equipped)
Use a guideline of 250 hours for use of the breaker (operat-
ing ratio for the breaker: 50 % or more), and replace the
element according to the table on the right.
X : Breaker operating ratio (%)
Y : Replacement interval (H)
(A): Hydraulic filter element
(B): Hydraulic oil
(C): Additional filter element
REMARK
Breaker operating ratio 100% means that only the breaker is
used
Breaker operating ratio 0% means that the breaker is not used
Summary of Contents for PC350LC-8
Page 2: ......
Page 3: ...FOREWORD 11...
Page 12: ...PRODUCT INFORMATION FOREWORD 1 10 SERVICE METER LOCATION 1 On top of the machine monitor...
Page 278: ...TROUBLES AND ACTIONS OPERATION 3 214...
Page 366: ...MAINTENANCE PROCEDURE MAINTENANCE 4 88...
Page 367: ...SPECIFICATIONS 15...
Page 371: ...SPECIFICATIONS SPECIFICATIONS 5 5...
Page 372: ...SPECIFICATIONS SPECIFICATIONS 5 6...
Page 432: ...SUPER LONG FRONT BOOM AND ARM ATTACHMENTS AND OPTIONS 6 60...
Page 496: ...SPECIFICATIONS HIGH REACH DEMOLITION MANUAL 7 64...
Page 497: ...INDEX 18...
Page 498: ...INDEX 8 2...
Page 501: ...COLOPHON 18...