5.
Remove the undercover(1) and (2).
6.
Set the oil container under the drain plug under the
machine. Using the handle, remove drain plug (P), (A) and
drain the oil. Check the O-ring installed to plug (P), (A), and
if it is damaged, replace the O-ring. After draining the oil,
tighten drain plug (P), (A).
q
Tightening torque of drain plug (P) and (A)
58.8 to 78.5 Nm (6 to 8 kgm)
q
When removing drain plug (P), (A), be careful not to
get oil on yourself.
q
First, remove drain plug (P) at the bottom of the tank,
then remove drain plug (A) at the suction tube. If they
are removed in this order, almost the same amount of
oil can be drained.
7.
Add the replacement amount of oil through oil filler (F). Check that the oil level is between the H and L lines on
the sight gauge (G).
For details of oil level check, see “Check Oil Level in Hydraulic Tank, Add Oil (3-125)“.
8.
Install the undercover (1) and (2).
9.
Bleed the air from the hydraulic circuit.
For details of the method of bleeding the air from the hydraulic circuit, see “BLEEDING AIR FROM HYDRAU-
LIC SYSTEM (4-46)“.
Summary of Contents for PC350LC-8
Page 2: ......
Page 3: ...FOREWORD 11...
Page 12: ...PRODUCT INFORMATION FOREWORD 1 10 SERVICE METER LOCATION 1 On top of the machine monitor...
Page 278: ...TROUBLES AND ACTIONS OPERATION 3 214...
Page 366: ...MAINTENANCE PROCEDURE MAINTENANCE 4 88...
Page 367: ...SPECIFICATIONS 15...
Page 371: ...SPECIFICATIONS SPECIFICATIONS 5 5...
Page 372: ...SPECIFICATIONS SPECIFICATIONS 5 6...
Page 432: ...SUPER LONG FRONT BOOM AND ARM ATTACHMENTS AND OPTIONS 6 60...
Page 496: ...SPECIFICATIONS HIGH REACH DEMOLITION MANUAL 7 64...
Page 497: ...INDEX 18...
Page 498: ...INDEX 8 2...
Page 501: ...COLOPHON 18...