OPERATION
DETAILED CONTROLS AND GAUGES
3-115
FUSE
3
NOTICE
Before replacing a fuse, be sure to turn off the starting switch.
q
The fuse holder is at the rear right of the operator's seat.
q
The fuses protect the electrical equipment and wiring from
burning out.
q
If the fuse becomes corroded, or white powder can be
seen, or the fuse is loose in the fuse holder, replace the
fuse.
q
Replace the fuse with another of the same capacity.
Fuse Capacities and Circuit Names
No.
Fuse
capacity
Name of circuit
(1)
10A
Working lamp relay, hazard switch
(2)
30A
Solenoid valve
(3)
10A
PPC hydraulic lock solenoid
(4)
10A
Window washer, cigarette lighter
(5)
10A
Horn
(6)
10A
Auto pre heater, lower wiper
(7)
10A
Rotating lamp, heated mirror (if fitted)
(8)
20A
Working lamp, rear lamp
(9)
10A
Radio, speaker, L.H. lever (power max,
quick coupler switch), hydraulic ladder,
quick coupler solenoid.
(10)
10A
Refuel pump.
(11)
20A
Air conditioner unit
(12)
20A
Rear worklamp
(13)
20A
Work lamp relay, cab lamp
(14)
30A
Optional power source (1), auto grease.
(15)
20A
Optional power source (2), travel alarm,
12V power supply,
heated air suspension seat
(16)
10A
Radio backup, room lamp
(17)
20A
Monitor (normal power source), pump
controller, starter switch
(18)
10A
Spare
(19)
30A
Engine controller
(20)
5A
Engine controller ACC
Summary of Contents for PC350LC-8
Page 2: ......
Page 3: ...FOREWORD 11...
Page 12: ...PRODUCT INFORMATION FOREWORD 1 10 SERVICE METER LOCATION 1 On top of the machine monitor...
Page 278: ...TROUBLES AND ACTIONS OPERATION 3 214...
Page 366: ...MAINTENANCE PROCEDURE MAINTENANCE 4 88...
Page 367: ...SPECIFICATIONS 15...
Page 371: ...SPECIFICATIONS SPECIFICATIONS 5 5...
Page 372: ...SPECIFICATIONS SPECIFICATIONS 5 6...
Page 432: ...SUPER LONG FRONT BOOM AND ARM ATTACHMENTS AND OPTIONS 6 60...
Page 496: ...SPECIFICATIONS HIGH REACH DEMOLITION MANUAL 7 64...
Page 497: ...INDEX 18...
Page 498: ...INDEX 8 2...
Page 501: ...COLOPHON 18...