background image

Infinity &

Infinity HD

RESIDENTIAL ELEVATORS

Planning Guide

Applicable Codes:

ASME A17.1/CSA-B44

Safety Code for Elevators and Escalators

Section 5.3 – Private Residential Elevators

Part No. 000783

24-m09-2015

 2015 Savaria Corporation

Summary of Contents for Infinity

Page 1: ...nity HD RESIDENTIAL ELEVATORS Planning Guide Applicable Codes ASME A17 1 CSA B44 Safety Code for Elevators and Escalators Section 5 3 Private Residential Elevators Part No 000783 24 m09 2015 2015 Savaria Corporation ...

Page 2: ...Copyright 2015 Savaria Corporation All Rights Reserved Printed in Canada ...

Page 3: ...th Auto Slim Doors planning information April 19 2011 Updated Auto Slim Door entrance assembly and elevation drawings in Appendix A August 12 2011 Revised Auto Slim Door entrance assembly drawings in Appendix A September 15 2011 Revised Auto Slim Door entrance assembly drawings in Appendix A August 30 2012 Revised Auto Slim Door elevation and plan view drawings in Appendix A November 6 2012 Added ...

Page 4: ...ity Guidelines as a means to provide public building access Design assistance With over 30 years of experience Savaria has the expertise to provide solutions to practically every design challenge you face Please call our Customer Service Department for professional advice at 800 661 5112 or 905 791 5555 Cab Cab operating panel COP Overhead clearance Hydraulic cylinder Guide rails Aircraft cables I...

Page 5: ... 3 4 and 5 36 x 48 914 mm x 1219 mm 36 x 54 914 mm x 1372 mm 36 x 60 914 mm x 1524 mm 40 x 54 1016 mm x 1372 mm Infinity HD Type 1L 1R 2 3 4 and 5 48 x 60 1219 mm x 1524 mm Cab panel finish Solid melamine or MDF panels standard Unfinished veneer optional Solid hardwood raised panels optional Hall call station and control panel finish Clear or bronze anodized aluminum standard Stainless steel or br...

Page 6: ...y Infinity HD cab types 3 4YPE 4YPE 2 4YPE 4YPE 4YPE 4YPE IMPORTANT Finished hoistway dimensions must include the drywall Determine the fire rating of the hoistway the type and layers of sheet rock and build only off the final installation shop drawings specific to your project ...

Page 7: ...nd wiring are provided and installed by others The light must be guarded to prevent accidental breakage of contact with the hot bulb The switch light wiring and guard are provided and installed by others A convenience outlet of 115V single phase 15 amp with G F I shall be located next to the light switch in the machine room provided and installed by others A telephone line circuit is to be provide...

Page 8: ...8 Infinity and Infinity HD Planning Guide Part No 000783 24 m09 2015 Machine room dimensions 5 ...

Page 9: ...28 711 mm Depth 17 432 mm Minimum required clearance 39 37 1000 mm Valve and manual lowering handle location Inside tank Rupture valve test T fitting factory installed Tank to controller wiring Quick connect valve and motor wiring Controller layout Relay board Keyed lock to tank Yes Machine room required No with local jurisdiction approval Tank capacity gal ltr 15 16 5 gal 57 63 ltr Maximum dry we...

Page 10: ... CONSULT YOUR 3AVARIA REPRESENTATIVE FOR EXACT LOCATION NTERMEDIATE RAIL BRACKET 2 IN MM INTERVALS ABOVE BOTTOM BRACKET OTTOM RAIL BRACKET 2 IN MM ABOVE PIT FLOOR IMPORTANT Always refer to your plan drawings for dimensions specific to your site For Infinity with Auto Slim Doors DO NOT use the above drawing refer to Appendix A instead ...

Page 11: ...finity HD Planning Guide Elevation view Infinity HD 8 4OP RAIL BRACKET AT TOP OF HOISTWAY CONSULT YOUR 3AVARIA REPRESENTATIVE FOR EXACT LOCATION NTERMEDIATE RAIL BRACKET IN MM INTERVALS ABOVE BOTTOM BRACKET OTTOM RAIL BRACKET IN MM ABOVE PIT FLOOR ...

Page 12: ...5 Plan view Infinity 36 x 48 type 1 left hand 9 Plan view Infinity 36 x 48 type 1 right hand 10 IMPORTANT Always refer to your plan drawings for dimensions specific to your site For Infinity with Auto Slim Doors DO NOT use the above drawings refer to Appendix A instead ...

Page 13: ...nning Guide Plan view Infinity 36 x 48 type 2 11 Plan view Infinity 36 x 48 type 3 12 IMPORTANT Always refer to your plan drawings for dimensions specific to your site For Infinity with Auto Slim Doors DO NOT use the above drawings refer to Appendix A instead ...

Page 14: ...24 m09 2015 Plan view Infinity 36 x 48 type 4 13 Plan view Infinity 36 x 48 type 5 14 IMPORTANT Always refer to your plan drawings for dimensions specific to your site For Infinity with Auto Slim Doors DO NOT use the above drawings refer to Appendix A instead ...

Page 15: ...e Plan view Infinity 36 x 54 type 1 left hand 15 Plan view Infinity 36 x 54 type 1 right hand 16 IMPORTANT Always refer to your plan drawings for dimensions specific to your site For Infinity with Auto Slim Doors DO NOT use the above drawings refer to Appendix A instead ...

Page 16: ...24 m09 2015 Plan view Infinity 36 x 54 type 2 17 Plan view Infinity 36 x 54 type 3 18 IMPORTANT Always refer to your plan drawings for dimensions specific to your site For Infinity with Auto Slim Doors DO NOT use the above drawings refer to Appendix A instead ...

Page 17: ...nning Guide Plan view Infinity 36 x 54 type 4 19 Plan view Infinity 36 x 54 type 5 20 IMPORTANT Always refer to your plan drawings for dimensions specific to your site For Infinity with Auto Slim Doors DO NOT use the above drawings refer to Appendix A instead ...

Page 18: ...5 Plan view Infinity 36 x 60 type 1 left hand 21 Plan view Infinity 36 x 60 type 1 right hand 22 IMPORTANT Always refer to your plan drawings for dimensions specific to your site For Infinity with Auto Slim Doors DO NOT use the above drawings refer to Appendix A instead ...

Page 19: ...nning Guide Plan view Infinity 36 x 60 type 2 23 Plan view Infinity 36 x 60 type 3 24 IMPORTANT Always refer to your plan drawings for dimensions specific to your site For Infinity with Auto Slim Doors DO NOT use the above drawings refer to Appendix A instead ...

Page 20: ...24 m09 2015 Plan view Infinity 36 x 60 type 4 25 Plan view Infinity 36 x 60 type 5 26 IMPORTANT Always refer to your plan drawings for dimensions specific to your site For Infinity with Auto Slim Doors DO NOT use the above drawings refer to Appendix A instead ...

Page 21: ...e Plan view Infinity 40 x 54 type 1 left hand 27 Plan view Infinity 40 x 54 type 1 right hand 28 IMPORTANT Always refer to your plan drawings for dimensions specific to your site For Infinity with Auto Slim Doors DO NOT use the above drawings refer to Appendix A instead ...

Page 22: ...24 m09 2015 Plan view Infinity 40 x 54 type 2 29 Plan view Infinity 40 x 54 type 3 30 IMPORTANT Always refer to your plan drawings for dimensions specific to your site For Infinity with Auto Slim Doors DO NOT use the above drawings refer to Appendix A instead ...

Page 23: ...nning Guide Plan view Infinity 40 x 54 type 4 31 Plan view Infinity 40 x 54 type 5 32 IMPORTANT Always refer to your plan drawings for dimensions specific to your site For Infinity with Auto Slim Doors DO NOT use the above drawings refer to Appendix A instead ...

Page 24: ...24 Infinity and Infinity HD Planning Guide Part No 000783 24 m09 2015 Plan view Infinity HD 48 x 60 type 1 left hand 33 ...

Page 25: ...25 Part No 000783 24 m09 2015 Infinity and Infinity HD Planning Guide Plan view Infinity HD 48 x 60 type 1 right hand 34 ...

Page 26: ...26 Infinity and Infinity HD Planning Guide Part No 000783 24 m09 2015 Plan view Infinity HD 48 x 60 type 2 35 ...

Page 27: ...27 Part No 000783 24 m09 2015 Infinity and Infinity HD Planning Guide Plan view Infinity HD 48 x 60 type 3 36 ...

Page 28: ...28 Infinity and Infinity HD Planning Guide Part No 000783 24 m09 2015 Plan view Infinity HD 48 x 60 type 4 37 ...

Page 29: ...29 Part No 000783 24 m09 2015 Infinity and Infinity HD Planning Guide Plan view Infinity HD 48 x 60 type 5 left hand gate stack door swing 38 ...

Page 30: ...30 Infinity and Infinity HD Planning Guide Part No 000783 24 m09 2015 Plan view Infinity HD 48 x 60 type 5 right hand gate stack door swing 39 ...

Page 31: ...aria com select the architects and builders tab at the top of the page and then select Doors and Gates from the menu on the left hand side of the page The link is as follows http www savaria com architects drawings doors gates index php Recommendation We recommend installation of a solid door as a hollow door may be too flexible and cause potential lock issues ...

Page 32: ...nfinity and Infinity HD Planning Guide Part No 000783 24 m09 2015 Loads on building and rail dimensions 41 Rail bracket dimensions Infinity Support wall orientation Rails Rail bracket dimensions Infinity HD ...

Page 33: ...ttom of the slab in two traverse directions and at a spacing of 12 305 mm Hoistway pit floor to support a load including impact of 5 6 kips 5600 lb 24 9 kN for Infinity or 8 22 kips 8220 lb 36 6 kN for Infinity HD Minimum overhead clearance of 92 2337 mm for 80 2032 mm cab 96 2438 mm for 84 cab and 108 2743 mm for 96 cab Minimum pit depth of 8 203 mm for Infinity and 12 305 mm for Infinity HD Hois...

Page 34: ...34 Infinity and Infinity HD Planning Guide Part No 000783 24 m09 2015 Masonry construction sectional view 43 ...

Page 35: ...35 Part No 000783 24 m09 2015 Infinity and Infinity HD Planning Guide Masonry construction plan view 44 ...

Page 36: ...36 Infinity and Infinity HD Planning Guide Part No 000783 24 m09 2015 Wood construction sectional view 45 For Reference Only ...

Page 37: ...37 Part No 000783 24 m09 2015 Infinity and Infinity HD Planning Guide Wood construction plan view 46 ...

Page 38: ...38 Infinity and Infinity HD Planning Guide Part No 000783 24 m09 2015 Suggested wall configuration for wood construction sheet 1 47 Refer to previous section Loads on building for rail forces R1 R2 R3 ...

Page 39: ...39 Part No 000783 24 m09 2015 Infinity and Infinity HD Planning Guide Suggested wall configuration for wood construction sheet 2 48 ...

Page 40: ...re applied to the wall from the floor or roof system and modify member sizes or connections as required by their analysis G4 Do not scale the drawings G5 See the lift installation shop drawings for service loads including dynamic effects which are Horizontal load parallel to the wall 194 lbf 0 86 kN for Infinity 251 lbf 1 12 kN for Infinity HD Horizontal load perpendicular to the wall 304 lbf 1 35...

Page 41: ... o Return walls at entrances must be built in by others after entrance assemblies are in place Entrance assembly must be securely fastened to walls by elevator contractor o Fascia panel below upper level entrance where required Fascia panel must be fastened to a solid wall and be perpendicular to the floor and walls Hoistway fascia is not self supporting for long continuous runs void of entrances ...

Page 42: ...ual 3 20 amp 3 20 amp 3 20 amp Cab Lighting 1 Pole Solid Neutral 120V 1 PH GP 111N 86211 CFN 211 Required Type D Fuse Buss type T or equal 1 15 amp 1 15 amp 1 15 amp Disconnect Switch Types Accessories Cutler Hammer Federal Pioneer Siemens 1 Phase 5 H P Pump Unit 2 Pole 240V 1 PH 1HD221N 1322SN ID321 Required Auxiliary Contact DS16CP E1K 1AEV W94 MSSAK 116 Required Type D Fuse Buss type FRN or equ...

Page 43: ...43 Part No 000783 24 m09 2015 Infinity and Infinity HD Planning Guide COP dimensions 51 ...

Page 44: ...44 Infinity and Infinity HD Planning Guide Part No 000783 24 m09 2015 Hall call dimensions 52 ...

Page 45: ...D Planning Guide Appendix A Infinity with Auto Slim Doors This appendix provides elevation and plan view drawings for the various Infinity cab types with Auto Slim Doors Drawings for the auto slim doors entrance assembly are provided on the next two pages ...

Page 46: ...46 Infinity and Infinity HD Planning Guide Part No 000783 24 m09 2015 Auto slim doors entrance assembly CO 2100 ...

Page 47: ...47 Part No 000783 24 m09 2015 Infinity and Infinity HD Planning Guide Elevation view Infinity type 1L with auto slim doors ...

Page 48: ...48 Infinity and Infinity HD Planning Guide Part No 000783 24 m09 2015 Plan view Infinity type 1L with auto slim doors ...

Page 49: ...49 Part No 000783 24 m09 2015 Infinity and Infinity HD Planning Guide Elevation view Infinity type 1R with auto slim doors ...

Page 50: ...50 Infinity and Infinity HD Planning Guide Part No 000783 24 m09 2015 Plan view Infinity type 1R with auto slim doors ...

Page 51: ...51 Part No 000783 24 m09 2015 Infinity and Infinity HD Planning Guide Elevation view Infinity type 2 with auto slim doors ...

Page 52: ...52 Infinity and Infinity HD Planning Guide Part No 000783 24 m09 2015 Plan view Infinity type 2 with auto slim doors ...

Page 53: ...53 Part No 000783 24 m09 2015 Infinity and Infinity HD Planning Guide Elevation view Infinity type 3 with auto slim doors ...

Page 54: ...54 Infinity and Infinity HD Planning Guide Part No 000783 24 m09 2015 Plan view Infinity type 3 with auto slim doors ...

Page 55: ...55 Part No 000783 24 m09 2015 Infinity and Infinity HD Planning Guide Elevation view Infinity type 4 with auto slim doors ...

Page 56: ...56 Infinity and Infinity HD Planning Guide Part No 000783 24 m09 2015 Plan view Infinity type 4 with auto slim doors ...

Page 57: ...57 Part No 000783 24 m09 2015 Infinity and Infinity HD Planning Guide Elevation view Infinity type 5 with auto slim doors ...

Page 58: ...58 Infinity and Infinity HD Planning Guide Part No 000783 24 m09 2015 Plan view Infinity type 5 with auto slim doors ...

Page 59: ......

Page 60: ...2 Walker Drive Brampton ON Canada L6T 5E1 Phone 905 791 5555 Fax 905 791 2222 Sales 800 661 5112 www savaria com ...

Reviews: