132
Keysight InfiniiVision 3000 X-Series Oscilloscopes User's Guide
8
Display Settings
3
To erase the results of previous acquisitions from the display, press the
Clear
Persistence
softkey.
The oscilloscope will start to accumulate acquisitions again.
4
To return the oscilloscope to the normal display mode, turn off persistence;
then, press the
Clear Persistence
softkey.
Turning off persistence does not clear the display. The display is cleared if you
press the
Clear Display
softkey or if you press the
[AutoScale]
key (which also
turns off persistence).
For another method of seeing worst-case extremes of varying waveforms, see
"Glitch or Narrow Pulse Capture"
To clear the display
1
Press
[Display] > Clear Display
.
You can also configure the
[Quick Action]
key to clear the display. See
To select the grid type
When the
Video
on page 160), and the
vertical scaling of at least one displayed channel is 140 mV/div, the
Grid
softkey
lets you select from these grid types:
•
Full
— the normal oscilloscope grid.
•
mV
— shows vertical grids, labeled on the left, from -0.3 V to 0.8 V.
•
IRE
— (Institute of Radio Engineers) shows vertical grids in IRE units, labeled on
the left, from -40 to 100 IRE. The 0.35 V and 0.7 V levels from the
mV
grid are
also shown and labeled at the right. When the
IRE
grid is selected, cursor values
are also shown in IRE units. (Cursor values via the remote interface are not in
IRE units.)
The
mV
and
IRE
grid values are accurate (and match Y cursor values) when the
vertical scaling is 140 mV/division and the vertical offset is 245 mV.
To select the grid type:
Summary of Contents for InfiniiVision 3000 X Series
Page 1: ...Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide...
Page 8: ...8 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide...
Page 24: ...24 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide...
Page 48: ...48 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 1 Getting Started...
Page 62: ...62 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 2 Horizontal Controls...
Page 72: ...72 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 3 Vertical Controls...
Page 122: ...122 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 6 Digital Channels...
Page 128: ...128 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 7 Serial Decode...
Page 134: ...134 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 8 Display Settings...
Page 182: ...182 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 11 Trigger Mode Coupling...
Page 200: ...200 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 12 Acquisition Control...
Page 210: ...210 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 13 Cursors...
Page 252: ...252 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 15 Mask Testing...
Page 256: ...256 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 16 Digital Voltmeter...
Page 290: ...290 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 19 Print Screens...
Page 324: ...324 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 21 Web Interface...
Page 344: ...344 Keysight InfiniiVision 3000 X Series Oscilloscopes User s Guide 22 Reference...