To display the multiple segment line:
1.
Press the
LIMIT
hot key.
2.
Press the
Multi Segment Line
soft key for Pass/Fail indication.
3.
Toggle the
Limit
soft key between
Upper
and
Lower
to select the one to be displayed.
4.
Set the number of segments for the selected upper or lower limit line. You can set up to 50
segments.
a.
Press the
# of Line
soft key.
b.
Enter a value between 1 and 50 by using the numeric keys.
c.
Press the
Enter
soft key.
5.
Press the
Autoset
soft key to let the instrument set the limit for each segment and display the
line.
6.
Optional
. To move the limit line, complete the following steps:
a.
Select
Limit Up/Down
or
Limit Left/Right
.
b.
Turn the rotary knob to move the line as desired. You can also manually enter a value.
7.
Optional
. To edit the segment properties, complete the following steps:
a.
Press the
Edit Limit
soft key.
b.
Press the
Move
soft key and then turn the rotary knob to select the segment to edit.
c.
Select the menu option, from the following choices:
–
To hide the line for the selected segment, toggle the
Line
soft key and select
Off
.
–
To add a new point, press the
Add Point
soft key.
–
To delete the selected point, press the
Delete Point
soft key.
–
To change the position, press the
Frequency
or
Amplitude
soft key, and then turn the
rotary knob to change the value as desired.
8.
Optional
. Go to
SAVE/LOAD
> Save
, and then select
Limit
to save the limit settings.
See
“Using save” on page 31 for more information.
Conducting RF measurements
Channel power
The Channel Power measurement is a common test used in the wireless industry to measure the total
transmitted power of a radio within a defined frequency channel. It acquires a number of points
representing the input signal in the time domain, transforms this information into the frequency domain
using Fast Fourier Transform (FFT), and then calculates the channel power. The effective resolution
bandwidth of the frequency domain trace is proportional to the number of points acquired for the FFT.
The channel power measurement identifies the total RF power, power spectral density, and Peak to
Average Ratio (PAR) of the signal within the channel bandwidth.
Setting measure setup
After configuring test parameters, you can set the measure setup to continue your measurement. The
measurement settings can be saved and recalled as a file. You can also use JDViewer, PC application
software to configure a measure setup, save as a file, and load the file on to the instrument.
Summary of Contents for CellAdvisor JD780A Series
Page 52: ...JD780A Series Analyzers 52 Getting Started Figure 6 Example of Web remote on Chrome...
Page 254: ...JD780A Series Analyzers 254 Using LTE FDD Signal Analyzer 3 RS SINR 4 S SS RSSI 5 P SS Power...
Page 323: ...JD780A Series Analyzers Using LTE TDD Signal Analyzer 323 3 RS SINR 4 S SS RSSI 5 P SS Power...
Page 390: ...JD780A Series Analyzers 390 Using EV DO Signal Analyzer 3 Pilot 4 MAC 64 5 MAC 128...
Page 525: ......
Page 590: ...JD780A Series Analyzers 590 Appendix Figure 306 Append keywords window...