![JDS Uniphase CellAdvisor JD780A Series User Manual Download Page 498](http://html1.mh-extra.com/html/jds-uniphase/celladvisor-jd780a-series/celladvisor-jd780a-series_user-manual_3602616498.webp)
JD780A Series Analyzers
498
Using Cable and Antenna Analyzer
9.
Connect the
Reflection/RF Out
port and the
RF In
port for the Cable and Antenna Analyzer with
the test cable and the proper adapter as illustrated in
.
10.
Press the
Continue
soft key to continue calibration.
The calibration progress bar appears.
After completion, the calibration status on the screen changes to
ON
.
O-S-L-Thru calibration using electronic EZ-Cal kit for vector measurements
illustrates the connection using the EZ-Cal kit for calibration in Vector measurements.
Figure 249
2-port calibration connection with EZ-Cal in vector measurements
1)
2)
Procedure
1.
Connect an extension cable, if necessary, to the
Reflection/RF Out
port of the instrument.
2.
Connect your
EZ-Cal
to the other open end of the extension cable or to your instrument's
Reflection/RF Out
port directly.
3.
Connect the USB cable to the side of the
EZ-Cal
and then to the
USB Host
port to power the
e-calibration kit as illustrated in
.
The instrument detects the EZ-Cal automatically and displays the EZ-Cal icon.
4.
Press the
MEASURE SETUP
hot key.
5.
Press the
Calibrate
soft key.
The on-screen instruction appears to guide you through the e-calibration.
6.
Connect the
Reflection/RF Out
port and the
RF In
port for the Cable and Antenna Analyzer with
the test cable and the proper adapter as illustrated in
.
7.
Press the
Continue
soft key to continue calibration.
The calibration progress bar appears.
After completion, the calibration status on the screen changes to
ON
.
Scalar measurement
illustrates the connection for calibration in Scalar measurements.
Summary of Contents for CellAdvisor JD780A Series
Page 52: ...JD780A Series Analyzers 52 Getting Started Figure 6 Example of Web remote on Chrome...
Page 254: ...JD780A Series Analyzers 254 Using LTE FDD Signal Analyzer 3 RS SINR 4 S SS RSSI 5 P SS Power...
Page 323: ...JD780A Series Analyzers Using LTE TDD Signal Analyzer 323 3 RS SINR 4 S SS RSSI 5 P SS Power...
Page 390: ...JD780A Series Analyzers 390 Using EV DO Signal Analyzer 3 Pilot 4 MAC 64 5 MAC 128...
Page 525: ......
Page 590: ...JD780A Series Analyzers 590 Appendix Figure 306 Append keywords window...