JD780A Series Analyzers
Using Power Meter
557
–
2
to display the reading with two decimal places
5.
To set a threshold and view the results with Pass/Fail indication, complete the following steps:
a.
Press the
LIMIT
hot key.
b.
Toggle the
Limit
soft key between
On
and
Off
to enable or disable the Pass/Fail indication.
c.
Press the
High Limit
soft key, and then enter a threshold value.
d.
Press the
dBm
unit soft key.
e.
Press the
Low Limit
soft key, and then enter a threshold value.
f.
Press the
dBm
unit soft key.
6.
Optional
. Go to
SAVE/LOAD
> Save
, and then select the save option from the choices available
for your measurement mode. See
“Using save” on page 31 for more information.
Measurement example
You can measure and understand a trend of a system output in operation where output power
constantly varies depending on the amount of calls being processed by the BTS or Repeater. In
addition, the Log graph benefits you to easily examine the discontinuance of output power caused by
the transmission problems or defective connection.
Figure 294
External power measurement of pulse power
Performing optical power measurements
The optical power measurement is available in conjunction with MP-series power sensor, which
measures optical power via a USB connection.
Connecting a power meter
Connecting an external optical power meter is mandatory for power measurements in the Optical
Power Meter mode. There are two optical power meters (sensors) those can be connected to the
instrument via USB. See
“JD780A Series Common Options” on page 585 for the optional power
meters.
Summary of Contents for CellAdvisor JD780A Series
Page 52: ...JD780A Series Analyzers 52 Getting Started Figure 6 Example of Web remote on Chrome...
Page 254: ...JD780A Series Analyzers 254 Using LTE FDD Signal Analyzer 3 RS SINR 4 S SS RSSI 5 P SS Power...
Page 323: ...JD780A Series Analyzers Using LTE TDD Signal Analyzer 323 3 RS SINR 4 S SS RSSI 5 P SS Power...
Page 390: ...JD780A Series Analyzers 390 Using EV DO Signal Analyzer 3 Pilot 4 MAC 64 5 MAC 128...
Page 525: ......
Page 590: ...JD780A Series Analyzers 590 Appendix Figure 306 Append keywords window...