JD780A Series Analyzers
68
Using Spectrum Analyzer
Display the input signal’s maximum response only
(unlimited or for a certain amount of time)
Max Hold
M
Display the input signal’s minimum
response only
(unlimited or for a certain amount of time)
Min Hold
m
Capture the selected trace and compare traces
Capture
C
Load a saved trace
More (1/2) > Load
L
Hide the selected trace
Trace View > Off
F
Remove all the traces and initialize the trace
settings
More (1/2) > Trace
Clear All
NOTE
For the
Max Hold
and
Min Hold
, your instrument compares newly acquired data with the
active trace and displays larger maximum values or smaller minimum values on the
screen. You can set it to
Unlimited
to hold and view maximum or minimum data or
specify a certain amount of time up to 60 seconds by using numeric keys or the rotary
knob.
4.
To select the detection option, press the
More (1/2) > Detectors
, and then do one of the
following:
To display
Select
Random noise better than the peak without missing signals
Normal
The highest value in each data point
Peak
The root mean squared average power across the spectrum
RMS
The lowest value in each data point
Negative Peak
The center value in each data point
Sample
5.
Optional
. Press the
More (1/2) > Trace Info
soft key, and then select the trace number to view
the trace
’s parameter setting information stored at the time of the measurement or
None
to hide
the information display.
6.
Optional.
If you have the two traces T1 and T2, you can perform trace math. To view the power
difference between the traces, press the
T1
– T2 -> T5
or
T2
– T1 -> T6
soft key.
The result is overlaid on the screen along with the second Y-axis.
NOTE
To be able to load a trace, the trace to be overlaid must be saved in the same
measurement mode and frequency setting as the current measurement.
Setting limit
Procedure
To use the display line:
1.
Press the
LIMIT
hot key.
2.
Press the
Display Line
soft key for a reference line.
3.
Enter a value, and then press the
dBm
unit soft key.
4.
Toggle the
Display Line
soft key between
On
and
Off
to display and dismiss the reference line.
The straight line appears across the screen to be used as a visual reference only.
Summary of Contents for CellAdvisor JD780A Series
Page 52: ...JD780A Series Analyzers 52 Getting Started Figure 6 Example of Web remote on Chrome...
Page 254: ...JD780A Series Analyzers 254 Using LTE FDD Signal Analyzer 3 RS SINR 4 S SS RSSI 5 P SS Power...
Page 323: ...JD780A Series Analyzers Using LTE TDD Signal Analyzer 323 3 RS SINR 4 S SS RSSI 5 P SS Power...
Page 390: ...JD780A Series Analyzers 390 Using EV DO Signal Analyzer 3 Pilot 4 MAC 64 5 MAC 128...
Page 525: ......
Page 590: ...JD780A Series Analyzers 590 Appendix Figure 306 Append keywords window...