2.
Press the
Settings
soft key and then set the following;
a.
Press the
Bandwidth
soft key and then select the nominal channel bandwidth to be
measured from the choices:
1.4 MHz
,
3 MHz
,
5 MHz
,
10 MHz
,
15 MHz
, and
20 MHz
:
b.
Press the
MIMO
soft key, and then select the antenna number option:
2x2
or
4x4
.
This MIMO (Multiple Input Multiple Output) setting is activated only if the option 030 LTE-
Advanced FDD is installed with a license number. If not, the instrument sets this option to
2x2 by default. A 2x1 or 4x1 RF combiner is also required to able to test on MIMO
channels.
c.
Toggle the
Cell ID
soft key and select
Auto
or
Manual
as desired:
–
Auto
: to let the instrument detect the Cell ID for the LTE signal automatically.
–
Manual
: to set a specific Cell ID for the LTE signal manually in order to speed up the
synchronization with a BTS.
d.
Press the
Antenna Port
soft key, and then select the option:
Auto
,
0
,
1
,
2
, or
3
.
If the option 030 LTE-Advanced FDD is not installed or if the MIMO is set to 2x2, the
antenna ports 2 and 3 are disabled.
e.
Toggle the
External Offset
soft key and select
On
to set the external offset value.
f.
To turn the Multimedia Broadcast Multicast Service (MBMS) feature on or off, toggle the
MBMS
soft key and select
On
or
Off
.
g.
To set the Multicast Broadcast Single Frequency Network (MBSFN) detection automatically
or manually for MBMS testing, toggle the
MBSFN
soft key and select
Auto
or
Manual
. An
automatically detected or manually entered MBSFN ID appears on the screen.
3.
To save your settings, go to
SAVE/LOAD
> Save > Save Setup
and then perform functions as
you desire. See
“Using save” on page 31 for more information.
4.
Press the
Continue
soft key to do the reference test first or press the
Skip Reference Test
soft
key if you already saved test results from the radio band under test.
5.
Press the
FREQ/DIST
hard key and then set the frequency to be measured. See
” on page 266 for more information.
6.
Press the
PREV
hard key.
7.
Press the
Limit
soft key and then set the limits and allowed percentage change for each test
item. See
“Maintenance test” on page 303 for more information on setting limits.
8.
Keep pressing the
PREV
hard key until you see the Run Test soft key.
9.
Press the
Run Test
soft key.
The instrument runs specified tests to gather reference measurement values. The measurement
table appears when the reference test is done.
10.
Press the
Continue
soft key to run the testing on an antenna (Ant 1).
11.
Optional
. To change the settings such as
External Offset
, press the
Settings
and then change
the settings as needed.
12.
Press the
Continue
soft key.
The instrument runs the testing on Ant 1. The Ant 1 tab appears with the updated result table
when the test is done.
13.
To run the testing on the next antenna (Ant 2), press the
Run Test
soft key and then repeat the
steps
11-12
. You can do the testing on up to 10 distributed antennas for one radio band.
14.
To view test results for each antenna, press the
Select Antenna
soft key and then select the
antenna tab number to display on the screen.
15.
Optional
. Press the
Delete
Test soft key to delete the selected antenna tab.
16.
Optional
. Press the
Retest Reference
soft key to obtain reference measurement values again.
17.
Optional
. To save your measurement results, go to
SAVE/LOAD
> Save
and then perform
functions as you desire. See
“Using save” on page 31 for more information.
Summary of Contents for CellAdvisor JD780A Series
Page 52: ...JD780A Series Analyzers 52 Getting Started Figure 6 Example of Web remote on Chrome...
Page 254: ...JD780A Series Analyzers 254 Using LTE FDD Signal Analyzer 3 RS SINR 4 S SS RSSI 5 P SS Power...
Page 323: ...JD780A Series Analyzers Using LTE TDD Signal Analyzer 323 3 RS SINR 4 S SS RSSI 5 P SS Power...
Page 390: ...JD780A Series Analyzers 390 Using EV DO Signal Analyzer 3 Pilot 4 MAC 64 5 MAC 128...
Page 525: ......
Page 590: ...JD780A Series Analyzers 590 Appendix Figure 306 Append keywords window...