![JDS Uniphase CellAdvisor JD780A Series User Manual Download Page 530](http://html1.mh-extra.com/html/jds-uniphase/celladvisor-jd780a-series/celladvisor-jd780a-series_user-manual_3602616530.webp)
JD780A Series Analyzers
530
Using T1 Analyzer
Measurement example
Figure 278
T1 transmission monitoring
Performing BERT testing
Making a test
Procedure
To select the measurement mode:
1.
Press the
MODE
hard key.
2.
Press the
E1/T1 Analyzer
soft key.
3.
Select
T1 Analyzer > BERT
.
To configure measurement parameters:
1.
Press the
MEASURE SETUP
hot key.
2.
Press the
RX Mode
soft key, and then select the receiver input option from the following choices:
–
Terminate
: Provides 100-ohm nominal input impedance, according to the framing, line
code, and BER pattern settings.
–
Bridge
: Provides input impedance greater than one kilohm for in-service monitoring,
bridging the receiver input across lines that are terminated elsewhere in the network.
–
Monitor
: Provides 100-ohm nominal input impedance for the in-service monitoring of T1
lines.
3.
Toggle the
Framing
soft key between
SF-D4
and
ESF
and select the framing type for your
receiver setting:
–
SF-D4 (Super Frame-D4):
Group of 12 frames, used to align equipment for framing.
–
ESF (Extended Super Frame):
Group of 24 frames, used to align equipment for framing.
4K for a maintenance channel (Facilities Data Link), 2K for CRC-6 checksum, and 2K for
framing/synchronization.
NOTE
If the framing type does not match with your receiver setting, a framing alarm occurs.
Summary of Contents for CellAdvisor JD780A Series
Page 52: ...JD780A Series Analyzers 52 Getting Started Figure 6 Example of Web remote on Chrome...
Page 254: ...JD780A Series Analyzers 254 Using LTE FDD Signal Analyzer 3 RS SINR 4 S SS RSSI 5 P SS Power...
Page 323: ...JD780A Series Analyzers Using LTE TDD Signal Analyzer 323 3 RS SINR 4 S SS RSSI 5 P SS Power...
Page 390: ...JD780A Series Analyzers 390 Using EV DO Signal Analyzer 3 Pilot 4 MAC 64 5 MAC 128...
Page 525: ......
Page 590: ...JD780A Series Analyzers 590 Appendix Figure 306 Append keywords window...