Using LTE - FDD Signal Analyzer
Measurement example
Figure 86
ACLR measurement with LTE - FDD signal analyzer
NOTE
You can use the
LIMIT
hot key to analyze your measurements with the user-definable
limit and Pass/Fail indication. See
“Setting limit for RF tests” on page 211 for more
information.
Multi-ACLR
The Multi-ACLR measurement is used to perform multi-channel ACLR measurements with as many
channels as possible. It helps you to measure ACLR in multi-channel transmitting Base Station
environment.
Setting measure setup
After configuring test parameters as described in the
“Configuring test parameters” on page 197, you
can continue your measurement.
Procedure
1.
Press the
MEASURE SETUP
hot key.
2.
To set the nominal channel bandwidth to be measured, complete the following steps:
a.
Press the
Bandwidth
soft key.
b.
Select the bandwidth option:
1.4 MHz
,
3 MHz
,
5 MHz
,
10 MHz
,
15 MHz
, or
20 MHz
.
3.
To set the frequency, do one of the following:
–
To set the center frequency, complete the following steps:
a.
Toggle the
Unit
soft key and select
Freq
.
b.
Press the
Lowest Frequency
soft key to set the starting center frequency.
c.
Enter a value by using the numeric keys. You can also use the rotary knob.
d.
Select the unit:
GHz
,
MHz
,
kHz
, or
Hz
.
e.
Press the
Highest Frequency
soft key to set the stopping center frequency.
Summary of Contents for CellAdvisor JD780A Series
Page 52: ...JD780A Series Analyzers 52 Getting Started Figure 6 Example of Web remote on Chrome...
Page 254: ...JD780A Series Analyzers 254 Using LTE FDD Signal Analyzer 3 RS SINR 4 S SS RSSI 5 P SS Power...
Page 323: ...JD780A Series Analyzers Using LTE TDD Signal Analyzer 323 3 RS SINR 4 S SS RSSI 5 P SS Power...
Page 390: ...JD780A Series Analyzers 390 Using EV DO Signal Analyzer 3 Pilot 4 MAC 64 5 MAC 128...
Page 525: ......
Page 590: ...JD780A Series Analyzers 590 Appendix Figure 306 Append keywords window...