JD780A Series Analyzers
Using E1 Analyzer
521
Monitoring transmission
Making a test
Procedure
To select the measurement mode:
1.
Press the
MODE
hard key.
2.
Press the
E1/T1 Analyzer
soft key.
3.
Select
E1 Analyzer > Monitoring
.
To configure measurement parameters:
1.
Press the
MEASURE SETUP
hot key.
2.
Press the
RX Mode
soft key, and then select the receiver input option from the following choices:
–
Terminate
: Provides 120-ohm nominal input impedance, according to the framing and line
code settings.
–
Bridge
: Provides input impedance greater than one kilohm for in-service monitoring,
bridging the receiver input across lines that are terminated elsewhere in the network.
–
Monitor
: Provides 120-ohm nominal input impedance for the in-service monitoring of E1
lines.
3.
Toggle the
Framing
soft key between
PCM30
and
PCM31
and select the framing type for your
receiver setting:
–
PCM30
: Timeslots from 1 to 15 correspond to channels from 1 to 15 and timeslots from 17
to 31 to channels from 16 to 30. Timeslot 16 is for the multi-frame alignment and Channel
Associated Signaling (CAS).
–
PCM31
: Timeslots from 1 to 31 correspond to channels from 1 to 31.
NOTE
If the framing type does not match with your receiver setting, a framing alarm occurs.
4.
Toggle the
Line Code
soft key between
AMI
and
HDB3
and select the line code type to send an
E1 signal:
–
AMI:
It stands for Alternate Mark Inversion. A line code uses one three level signal to
convey binary digits in which successive binary ones (
“marks” or pulses) are of alternating
polarity, either positive or negative, equal in amplitude. A binary zero
(“space”) is
transmitted as no pulse or zero amplitude.
–
HDB3:
It stands for High Density Bipolar order 3 encoding. It is a bipolar signaling
technique (using both positive and negative pulses) based on the AMI. It extends AMI by
inserting violation codes whenever there is a run of four or more zeros.
To start or stop monitoring:
1.
Press the
MEASURE
hot key.
2.
Press the
Monitoring
soft key, and then select the monitoring option as needed:
Start
,
Stop
, or
Clear
.
Optional
. You can save event records automatically by using the
Save Logging Data
soft key. See
“Using save” on page 31 for more information.
Summary of Contents for CellAdvisor JD780A Series
Page 52: ...JD780A Series Analyzers 52 Getting Started Figure 6 Example of Web remote on Chrome...
Page 254: ...JD780A Series Analyzers 254 Using LTE FDD Signal Analyzer 3 RS SINR 4 S SS RSSI 5 P SS Power...
Page 323: ...JD780A Series Analyzers Using LTE TDD Signal Analyzer 323 3 RS SINR 4 S SS RSSI 5 P SS Power...
Page 390: ...JD780A Series Analyzers 390 Using EV DO Signal Analyzer 3 Pilot 4 MAC 64 5 MAC 128...
Page 525: ......
Page 590: ...JD780A Series Analyzers 590 Appendix Figure 306 Append keywords window...