![JDS Uniphase CellAdvisor JD780A Series User Manual Download Page 222](http://html1.mh-extra.com/html/jds-uniphase/celladvisor-jd780a-series/celladvisor-jd780a-series_user-manual_3602616222.webp)
JD780A Series Analyzers
222
Using LTE - FDD Signal Analyzer
–
Combine:
Testing on multiple antennas connected to your JD780A series with a 2x1 or 4x1
combiner or an antenna.
8.
Optional
. Press the
Miscellaneous
soft key, and then do the following(s) as needed:
–
To select the number of antenna ports, toggle the
MIMO
soft key and select
2x2
or
4x4
.
This MIMO (Multiple Input Multiple Output) setting is activated only if the option 030 LTE-
Advanced FDD is installed with a license number. If not, the instrument sets this option to
2x2 by default. A 2x1 or 4x1 RF combiner is also required to able to test on MIMO
channels.
–
To assign a antenna port number automatically or manually, press the
Antenna Port
soft
key and select the option:
Auto
,
0
,
1
,
2
, and
3
. If the option 030 LTE-Advanced FDD is not
installed or if the MIMO is set to 2x2, the antenna ports 2 and 3 are disabled.
–
To turn the Multimedia Broadcast Multicast Service (MBMS) feature on or off, toggle the
MBMS
soft key and select
On
or
Off
. For proper MBMS testing, you need to set the
Subframe No
with the same PMCH subframe number. If this setting is on, the
measurement item
“MBSFN RS” appears in the result table and either PMCH or PDSCH
appears as well depending on the detected channel.
–
To set the Multicast Broadcast Single Frequency Network (MBSFN) detection automatically
or manually for MBMS testing, toggle the
MBSFN
soft key and select
Auto
or
Manual
. An
automatically detected or manually entered MBSFN ID appears on the screen.
–
To select the cyclic prefix, toggle the
Cyclic Prefix
soft key and select
Normal
or
Extended
. See
“Appendix E – Cyclic prefix table” on page 575 for OFDM parameter details
by different bandwidth.
–
Press the
PDSCH Modulation Type
soft key, and then select the modulation type option:
Auto
,
QPSK
,
16 QAM
,
64 QAM
,
E-TM3.3
,
E-TM3.2
,
E-TM3.1
,
E-TM2
,
E-TM1.2
, and
E-
TM1.1
. If two or more modulation types are used in a frame, select
Auto
. If the PDSCH
uses the same modulation type in a frame or in a subframe, select a specific modulation
type to get more accurate EVM.
–
To set the threshold for PDSCH, complete the following steps:
a.
Press the
PDSCH Threshold
soft key.
b.
Enter a value by using the numeric keys.
c.
Press the
dB
soft key.
–
To set the threshold for PDCCH, complete the following steps:
a.
Press the
PDCCH Threshold
soft key.
b.
Enter a value by using the numeric keys.
c.
Press the
dB
soft key.
–
Toggle the
PDCCH Mode
soft key and select
REG
to calculate EVM based on Resource
Element Group or
Avg
to calculate EVM after adding up all the PDCCH signals from one
subframe.
–
Toggle the
PDSCH Precoding
soft key between
On
and
Off
to enable or disable the
PDSCH precoding.
Summary of Contents for CellAdvisor JD780A Series
Page 52: ...JD780A Series Analyzers 52 Getting Started Figure 6 Example of Web remote on Chrome...
Page 254: ...JD780A Series Analyzers 254 Using LTE FDD Signal Analyzer 3 RS SINR 4 S SS RSSI 5 P SS Power...
Page 323: ...JD780A Series Analyzers Using LTE TDD Signal Analyzer 323 3 RS SINR 4 S SS RSSI 5 P SS Power...
Page 390: ...JD780A Series Analyzers 390 Using EV DO Signal Analyzer 3 Pilot 4 MAC 64 5 MAC 128...
Page 525: ......
Page 590: ...JD780A Series Analyzers 590 Appendix Figure 306 Append keywords window...