![JDS Uniphase CellAdvisor JD780A Series User Manual Download Page 245](http://html1.mh-extra.com/html/jds-uniphase/celladvisor-jd780a-series/celladvisor-jd780a-series_user-manual_3602616245.webp)
JD780A Series Analyzers
Using LTE - FDD Signal Analyzer
245
ID scanner
The LTE mobile receives signals from multiple base stations that all of these signals share the same
spectrum and are present at the same time. Each base station has unique scrambling code assigned
to the particular base station and it differentiates its signal from other base stations in the area.
The ID Scanner shows key parameters such as RSRP (Reference Signal Received Power) and RSRQ
(Reference Signal Received Quality) that predict the downlink coverage quickly.
RSRPs from entire cells help to rank between the different cells as input for handover and cell
reselection decisions.
RSRQ provides additional information when RSRP is not sufficient to make a reliable
handover or cell reselection decision.
All of the parameters for OTA ID scanner can be plotted on map data such as Google Maps and
Google Earth by using JDViewer.
Setting measure setup
After configuring test parameters as described in the
“Configuring test parameters” on page 197, you
can continue your measurement.
Procedure
1.
Press the
MEASURE SETUP
hot key.
2.
To set the nominal channel bandwidth to be measured, complete the following steps:
a.
Press the
Bandwidth
soft key.
b.
Select the bandwidth option:
1.4 MHz
,
3 MHz
,
5 MHz
,
10 MHz
,
15 MHz
, or
20 MHz
.
3.
Optional
. Press the
Miscellaneous
soft key, and then do the following(s) as needed:
–
To select the number of antenna ports, toggle the
MIMO
soft key and select
2x2
or
4x4
.
This MIMO (Multiple Input Multiple Output) setting is activated only if the option 030 LTE-
Advanced FDD is installed with a license number. If not, the instrument sets this option to
2x2 by default. A 2x1 or 4x1 RF combiner is also required to able to test on MIMO
channels.
–
To select the cyclic prefix, toggle the
Cyclic Prefix
soft key and select
Normal
or
Extended
. See
“Appendix E – Cyclic prefix table” on page 575 for OFDM parameter details
by different bandwidth.
4.
Optional
. Go to
SAVE/LOAD
> Save
, and then select the save option from the choices available
for your measurement mode. See
“Using save” on page 31 for more information.
Summary of Contents for CellAdvisor JD780A Series
Page 52: ...JD780A Series Analyzers 52 Getting Started Figure 6 Example of Web remote on Chrome...
Page 254: ...JD780A Series Analyzers 254 Using LTE FDD Signal Analyzer 3 RS SINR 4 S SS RSSI 5 P SS Power...
Page 323: ...JD780A Series Analyzers Using LTE TDD Signal Analyzer 323 3 RS SINR 4 S SS RSSI 5 P SS Power...
Page 390: ...JD780A Series Analyzers 390 Using EV DO Signal Analyzer 3 Pilot 4 MAC 64 5 MAC 128...
Page 525: ......