![JDS Uniphase CellAdvisor JD780A Series User Manual Download Page 136](http://html1.mh-extra.com/html/jds-uniphase/celladvisor-jd780a-series/celladvisor-jd780a-series_user-manual_3602616136.webp)
JD780A Series Analyzers
136
Using GSM/GPRS/EDGE Signal Analyzer
Measurement example
Figure 44
Spurious emissions measurement with GSM signal analyzer
NOTE
You can use the
LIMIT
hot key to analyze your measurements with the user-definable
limit and Pass/Fail indication. See
“Setting limit for RF tests” on page 136 for more
information.
Setting limit for RF tests
By default, test limits specified in the standard are set for you. You can change thresholds if you desire.
Procedure
1.
Press the
LIMIT
hot key.
2.
Press the
RF Test Limits
soft key.
3.
Select the test item(s) and set the limit(s) depending on your selected measurement mode:
To set the limit for
Select
Set
Channel power
Channel Power
High Limit, Low Limit
Occupied bandwidth
Occupied BW
High Limit
Spectrum emission mask
Spectrum Emission Mask
(On/Off only)
Output RF spectrum
Output RF Spectrum
(On/Off only)
Spurious emissions
Spurious Emissions
(On/Off only)
4.
Optional
. You can enable alarm sound that goes off if the measurement falls outside of the limit.
Toggle the
Beep
soft key between
On
and
Off
to enable or disable the beep sound.
5.
Optional
. Go to
SAVE/LOAD
> Save
, and then select
Limit
to save the limit settings.
See
“Using save” on page 31 for more information.
Summary of Contents for CellAdvisor JD780A Series
Page 52: ...JD780A Series Analyzers 52 Getting Started Figure 6 Example of Web remote on Chrome...
Page 254: ...JD780A Series Analyzers 254 Using LTE FDD Signal Analyzer 3 RS SINR 4 S SS RSSI 5 P SS Power...
Page 323: ...JD780A Series Analyzers Using LTE TDD Signal Analyzer 323 3 RS SINR 4 S SS RSSI 5 P SS Power...
Page 390: ...JD780A Series Analyzers 390 Using EV DO Signal Analyzer 3 Pilot 4 MAC 64 5 MAC 128...
Page 525: ......
Page 590: ...JD780A Series Analyzers 590 Appendix Figure 306 Append keywords window...